Development of a method to create uniform phantoms for task‐based assessment of CT image quality. Issue 9 (28th July 2020)
- Record Type:
- Journal Article
- Title:
- Development of a method to create uniform phantoms for task‐based assessment of CT image quality. Issue 9 (28th July 2020)
- Main Title:
- Development of a method to create uniform phantoms for task‐based assessment of CT image quality
- Authors:
- Conzelmann, Juliane
Schwarz, Felix Benjamin
Hamm, Bernd
Scheel, Michael
Jahnke, Paul - Abstract:
- Abstract: Purpose: To develop a customized method to produce uniform phantoms for task‐based assessment of CT image quality. Methods: Contrasts between polymethyl methacrylate (PMMA) and fructose solutions of different concentrations (240, 250, 260, 280, 290, 300, 310, 320, 330, and 340 mg/mL) were calculated. A phantom was produced by laser cutting PMMA slabs to the shape of a patient's neck. An opening of 10 mm diameter was cut into the left parapharyngeal space. An angioplasty balloon was inserted and filled with the fructose solutions to simulate low‐contrast lesions. The phantom was scanned with six tube currents. Images were reconstructed with filtered back projection (FBP) and adaptive iterative dose reduction 3D (AIDR 3D). Calculated and measured contrasts were compared. The phantom was evaluated in a detectability experiment using images with 4 and 20 HU lesion contrast. Results: Low‐contrast lesions of 4, 9, 11, 13, 18, 20, 24, 30, 35, and 37 HU contrast were simulated. Calculated and measured contrasts correlated excellently (r = 0.998; 95% confidence interval: 0.991 to 1). The mean ± SD difference was 0.41 ± 2.32 HU ( P < 0.0001). Detection accuracy and reader confidence were 62.9 ± 18.2% and 1.58 ± 0.68 for 4 HU lesion contrast and 99.6 ± 1.3% and 4.27 ± 0.92 for 20 HU lesion contrast ( P < 0.0001), confirming that the method produced lesions at the threshold of detectability. Conclusion: A cost‐effective and flexible approach was developed to create uniformAbstract: Purpose: To develop a customized method to produce uniform phantoms for task‐based assessment of CT image quality. Methods: Contrasts between polymethyl methacrylate (PMMA) and fructose solutions of different concentrations (240, 250, 260, 280, 290, 300, 310, 320, 330, and 340 mg/mL) were calculated. A phantom was produced by laser cutting PMMA slabs to the shape of a patient's neck. An opening of 10 mm diameter was cut into the left parapharyngeal space. An angioplasty balloon was inserted and filled with the fructose solutions to simulate low‐contrast lesions. The phantom was scanned with six tube currents. Images were reconstructed with filtered back projection (FBP) and adaptive iterative dose reduction 3D (AIDR 3D). Calculated and measured contrasts were compared. The phantom was evaluated in a detectability experiment using images with 4 and 20 HU lesion contrast. Results: Low‐contrast lesions of 4, 9, 11, 13, 18, 20, 24, 30, 35, and 37 HU contrast were simulated. Calculated and measured contrasts correlated excellently (r = 0.998; 95% confidence interval: 0.991 to 1). The mean ± SD difference was 0.41 ± 2.32 HU ( P < 0.0001). Detection accuracy and reader confidence were 62.9 ± 18.2% and 1.58 ± 0.68 for 4 HU lesion contrast and 99.6 ± 1.3% and 4.27 ± 0.92 for 20 HU lesion contrast ( P < 0.0001), confirming that the method produced lesions at the threshold of detectability. Conclusion: A cost‐effective and flexible approach was developed to create uniform phantoms with low‐contrast signals. The method should facilitate access to customized phantoms for task‐based image quality assessment. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 9(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 9(2020)
- Issue Display:
- Volume 21, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 9
- Issue Sort Value:
- 2020-0021-0009-0000
- Page Start:
- 201
- Page End:
- 208
- Publication Date:
- 2020-07-28
- Subjects:
- contrast sensitivity -- phantoms -- imaging -- tomography -- x‐ray computed
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12974 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14320.xml