Very long-term survival and late sudden cardiac death in cardiac resynchronization therapy patients. (2nd May 2019)
- Record Type:
- Journal Article
- Title:
- Very long-term survival and late sudden cardiac death in cardiac resynchronization therapy patients. (2nd May 2019)
- Main Title:
- Very long-term survival and late sudden cardiac death in cardiac resynchronization therapy patients
- Authors:
- Barra, Sérgio
Duehmke, Rudolf
Providência, Rui
Narayanan, Kumar
Reitan, Christian
Roubicek, Tomas
Polasek, Rostislav
Chow, Antony
Defaye, Pascal
Fauchier, Laurent
Piot, Olivier
Deharo, Jean-Claude
Sadoul, Nicolas
Klug, Didier
Garcia, Rodrigue
Dockrill, Seth
Virdee, Munmohan
Pettit, Stephen
Agarwal, Sharad
Borgquist, Rasmus
Marijon, Eloi
Boveda, Serge - Abstract:
- Abstract: Aims: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). Methods and results: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10–42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3–45.5] and 97.2 (95% CI 85.5–109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79–1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45–2.44). Death due to progressive heart failure represented the principal cause of deathAbstract: Aims: The very long-term outcome of patients who survive the first few years after receiving cardiac resynchronization therapy (CRT) has not been well described thus far. We aimed to provide long-term outcomes, especially with regard to the occurrence of sudden cardiac death (SCD), in CRT patients without (CRT-P) and with defibrillator (CRT-D). Methods and results: A total of 1775 patients, with ischaemic or non-ischaemic dilated cardiomyopathy, who were alive 5 years after CRT implantation, were enrolled in this multicentre European observational cohort study. Overall long-term mortality rates and specific causes of death were assessed, with a focus on late SCD. Over a mean follow-up of 30 months (interquartile range 10–42 months) beyond the first 5 years, we observed 473 deaths. The annual age-standardized mortality rates of CRT-D and CRT-P patients were 40.4 [95% confidence interval (CI) 35.3–45.5] and 97.2 (95% CI 85.5–109.9) per 1000 patient-years, respectively. The adjusted hazard ratio (HR) for all-cause mortality was 0.99 (95% CI 0.79–1.22). Twenty-nine patients in total died of late SCD (14 with CRT-P, 15 with CRT-D), corresponding to 6.1% of all causes of death in both device groups. Specific annual SCD rates were 8.5 and 5.8 per 1000 patient-years in CRT-P and CRT-D patients, respectively, with no significant difference between groups (adjusted HR 1.0, 95% CI 0.45–2.44). Death due to progressive heart failure represented the principal cause of death (42.8% in CRT-P patients and 52.6% among CRT-D recipients), whereas approximately one-third of deaths in both device groups were due to non-cardiovascular death. Conclusion: In this first description of very long-term outcomes among CRT recipients, progressive heart failure death still represented the most frequent cause of death in patients surviving the first 5 years after CRT implant. In contrast, SCD represents a very low proportion of late mortality irrespective of the presence of a defibrillator. … (more)
- Is Part Of:
- European heart journal. Volume 40:Number 26(2019)
- Journal:
- European heart journal
- Issue:
- Volume 40:Number 26(2019)
- Issue Display:
- Volume 40, Issue 26 (2019)
- Year:
- 2019
- Volume:
- 40
- Issue:
- 26
- Issue Sort Value:
- 2019-0040-0026-0000
- Page Start:
- 2121
- Page End:
- 2127
- Publication Date:
- 2019-05-02
- Subjects:
- Cardiac resynchronization therapy -- Implantable cardioverter-defibrillator -- Cause of death -- Sudden cardiac death -- Heart failure
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehz238 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14313.xml