Use of an innovative and non-invasive device for virologic sampling of cough aerosols in patients with community and hospital acquired pneumonia: a pilot study. (1st March 2019)
- Record Type:
- Journal Article
- Title:
- Use of an innovative and non-invasive device for virologic sampling of cough aerosols in patients with community and hospital acquired pneumonia: a pilot study. (1st March 2019)
- Main Title:
- Use of an innovative and non-invasive device for virologic sampling of cough aerosols in patients with community and hospital acquired pneumonia: a pilot study
- Authors:
- Patrucco, Filippo
Gavelli, Francesco
Ravanini, Paolo
Daverio, Matteo
Statti, Giulia
Castello, Luigi Mario
Andreoni, Stefano
Balbo, Piero Emilio - Abstract:
- Abstract: Background : The aetiology of lower respiratory tract infections is challenging to investigate. Despite the wide array of diagnostic tools, invasive techniques, such as bronchoalveolar lavage (BAL), are often required to obtain adequate specimens. PneumoniaCheck TM is a new device that collects aerosol particles from cough, allowing microbiological analyses. Up to now it has been tested only for bacteria detection, but no study has investigated its usefulness for virus identification. Methods : In this pilot study we included 12 consecutive patients with pneumonia. After testing cough adequacy via a peak flow meter, a sampling with PneumoniaCheck TM was collected and a BAL was performed in each patient. Microbiological analyses for virus identification were performed on each sample and concordance between the two techniques was tested (sensitivity, specificity and positive/negative predictive values), taking BAL results as reference. Results : BAL was considered adequate in 10 patients. Among them, a viral pathogen was identified by PneumoniaCheck TM 6 times, each on different samples, whereas BAL allowed to detect the presence of a virus on 7 patients (14 positivities). Overall, the specificity for PneumoniaCheck TM to detect a virus was 100%, whereas the sensitivity was 66%. When considering only herpes viruses, PneumoniaCheck TM showed a lower sensitivity, detecting a virus in 1/4 of infected patients (25%). Conclusions : In this pilot study PneumoniaCheck TMAbstract: Background : The aetiology of lower respiratory tract infections is challenging to investigate. Despite the wide array of diagnostic tools, invasive techniques, such as bronchoalveolar lavage (BAL), are often required to obtain adequate specimens. PneumoniaCheck TM is a new device that collects aerosol particles from cough, allowing microbiological analyses. Up to now it has been tested only for bacteria detection, but no study has investigated its usefulness for virus identification. Methods : In this pilot study we included 12 consecutive patients with pneumonia. After testing cough adequacy via a peak flow meter, a sampling with PneumoniaCheck TM was collected and a BAL was performed in each patient. Microbiological analyses for virus identification were performed on each sample and concordance between the two techniques was tested (sensitivity, specificity and positive/negative predictive values), taking BAL results as reference. Results : BAL was considered adequate in 10 patients. Among them, a viral pathogen was identified by PneumoniaCheck TM 6 times, each on different samples, whereas BAL allowed to detect the presence of a virus on 7 patients (14 positivities). Overall, the specificity for PneumoniaCheck TM to detect a virus was 100%, whereas the sensitivity was 66%. When considering only herpes viruses, PneumoniaCheck TM showed a lower sensitivity, detecting a virus in 1/4 of infected patients (25%). Conclusions : In this pilot study PneumoniaCheck TM showed a good correlation with BAL for non-herpes virologic identification in pneumonia patients, providing excellent specificity. Further studies on larger population are needed to confirm these results and define its place in the panorama of rapid diagnostic tests for lower respiratory tract infections. … (more)
- Is Part Of:
- Journal of breath research. Volume 13:Number 2(2019:Jun.)
- Journal:
- Journal of breath research
- Issue:
- Volume 13:Number 2(2019:Jun.)
- Issue Display:
- Volume 13, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 13
- Issue:
- 2
- Issue Sort Value:
- 2019-0013-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03-01
- Subjects:
- pneumonia -- virus -- cough -- bronchoalveolar lavage -- rapid diagnostic test
Volatile organic compounds -- Analysis -- Periodicals
Clinical chemistry -- Periodicals
Bad breath -- Periodicals
Bad breath -- Treatment -- Periodicals
Bad breath -- Diagnosis -- Periodicals
616.0756 - Journal URLs:
- http://iopscience.iop.org/1752-7163/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1752-7163/aaf010 ↗
- Languages:
- English
- ISSNs:
- 1752-7155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14308.xml