Changing the syringe pump: A challenging procedure in critically ill patients. Issue 6 (November 2020)
- Record Type:
- Journal Article
- Title:
- Changing the syringe pump: A challenging procedure in critically ill patients. Issue 6 (November 2020)
- Main Title:
- Changing the syringe pump: A challenging procedure in critically ill patients
- Authors:
- Elli, Stefano
Mattiussi, Elisa
Bambi, Stefano
Tupputi, Serena
San Fratello, Salvatore
De Nunzio, Angela
D'Auria, Salvatore
Rona, Roberto
Fumagalli, Roberto
Lucchini, Alberto - Abstract:
- Introduction: In the literature, the change of a syringe pump is described as a dangerous situation, especially in the case of vasoactive drug administration. Methods: Different variables have been studied (central venous pressure, pump displacement in relation to the patient position, utilization of a stopcock, or a neutral displacement needle-free connector between the syringe and the infusion tubing) to understand their influence on medication administration in terms of backflow or bolus creation when changing the syringe. Results: We performed 576 measurements with different combinations. With respect to all the observations, in comparison with "time zero, " we found the following differences expressed in microliters: 0 (±1) at the plunger opening; 0 (±3) at the syringe extraction from the pump; 0 (±7) at the syringe disconnection from the infusion tubing; 0 (±11) at the syringe reconnection to the infusion tubing; 1 (±7) at the syringe insertion in the pump; 3 (±23) at the plunger closing; 8 (±33) at the stabilization at the maneuver end. Conclusion: The syringe change can be a very critical moment given different influencing variables. Syringe pump position, displaced higher than the patient level, always generates a medication bolus that is higher at the lowering of the central venous pressure value. The presence of a neutral displacement needle-free connector reduces the incidence of boluses. When the pump is placed at the patient level, the presence of neutralIntroduction: In the literature, the change of a syringe pump is described as a dangerous situation, especially in the case of vasoactive drug administration. Methods: Different variables have been studied (central venous pressure, pump displacement in relation to the patient position, utilization of a stopcock, or a neutral displacement needle-free connector between the syringe and the infusion tubing) to understand their influence on medication administration in terms of backflow or bolus creation when changing the syringe. Results: We performed 576 measurements with different combinations. With respect to all the observations, in comparison with "time zero, " we found the following differences expressed in microliters: 0 (±1) at the plunger opening; 0 (±3) at the syringe extraction from the pump; 0 (±7) at the syringe disconnection from the infusion tubing; 0 (±11) at the syringe reconnection to the infusion tubing; 1 (±7) at the syringe insertion in the pump; 3 (±23) at the plunger closing; 8 (±33) at the stabilization at the maneuver end. Conclusion: The syringe change can be a very critical moment given different influencing variables. Syringe pump position, displaced higher than the patient level, always generates a medication bolus that is higher at the lowering of the central venous pressure value. The presence of a neutral displacement needle-free connector reduces the incidence of boluses. When the pump is placed at the patient level, the presence of neutral displacement needle-free connector reduces the establishment of boluses, even in a central venous pressure of −5 mmHg simulations. … (more)
- Is Part Of:
- Journal of vascular access. Volume 21:Issue 6(2020)
- Journal:
- Journal of vascular access
- Issue:
- Volume 21:Issue 6(2020)
- Issue Display:
- Volume 21, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 6
- Issue Sort Value:
- 2020-0021-0006-0000
- Page Start:
- 868
- Page End:
- 874
- Publication Date:
- 2020-11
- Subjects:
- Backflow -- bolus -- changeover -- infusion -- inotrope infusion -- needle-free connector -- syringe pump vasoactive drug pumping -- vasoactive drug administration
Arterial catheterization -- Periodicals
Intravenous catheterization -- Periodicals
612.13 - Journal URLs:
- http://journals.sagepub.com/home/jva ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1129729820909024 ↗
- Languages:
- English
- ISSNs:
- 1129-7298
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14296.xml