Biomechanical Comparison of a New Memory Compression Alloy Plate versus Traditional Titanium Plate for Anterior Cervical Discectomy and Fusion: A Finite Element Analysis. (17th July 2020)
- Record Type:
- Journal Article
- Title:
- Biomechanical Comparison of a New Memory Compression Alloy Plate versus Traditional Titanium Plate for Anterior Cervical Discectomy and Fusion: A Finite Element Analysis. (17th July 2020)
- Main Title:
- Biomechanical Comparison of a New Memory Compression Alloy Plate versus Traditional Titanium Plate for Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
- Authors:
- Liu, Jiantao
Wang, Runqing
Wang, Hongbo
Wang, Yanbiao
Lv, Dongbo
Diao, Pan
Feng, Shihan
Gao, Yanzheng - Other Names:
- Wang Aijun Academic Editor.
- Abstract:
- Abstract : Objective . To compare the biomechanical properties of a new memory compression alloy plate and traditional titanium plate after anterior cervical discectomy and fusion (ACDF). Methods . A finite element model of the C3-7 segments was developed and validated. The C5-6 disc was removed, and an intervertebral cage made of peek material was implanted. Then, a new memory compression alloy plate composed of Ti-Ni memory alloy and a traditional titanium plate were integrated at the C5-6 segment. All models were subjected to a load of 73.6 N to simulate the head weight and 1 Nm of flexion-extension, lateral bending, and axial rotation. The range of segmental motion (ROM) and stress on the prostheses, adjacent discs, and endplates were analyzed. Results . Compared with intact status, ACDF with the new prothesis and traditional titanium plate reduced the ROM of C5-6 in six directions by 95.2%-100% and increased that of adjacent discs (C4-5 and C6-7) by 4.8%-112.5%. Adjacent disc stress peaks were higher for the traditional titanium plate (0.7-4.2 MPa) than for the new prosthesis (0.6-4.1 MPa). Endplate stress peaks were the highest in ACDF with the new prosthesis (15.6-53.3 MPa), followed by ACDF with traditional titanium plate (5.0-29.4 MPa). Stress peaks were significantly lower for the new prothesis (12.8-52.3 MPa) than for the traditional titanium plate (397.0-666.1 MPa). Conclusions . The new prosthesis improved the immediate stability of the surgical site and had anAbstract : Objective . To compare the biomechanical properties of a new memory compression alloy plate and traditional titanium plate after anterior cervical discectomy and fusion (ACDF). Methods . A finite element model of the C3-7 segments was developed and validated. The C5-6 disc was removed, and an intervertebral cage made of peek material was implanted. Then, a new memory compression alloy plate composed of Ti-Ni memory alloy and a traditional titanium plate were integrated at the C5-6 segment. All models were subjected to a load of 73.6 N to simulate the head weight and 1 Nm of flexion-extension, lateral bending, and axial rotation. The range of segmental motion (ROM) and stress on the prostheses, adjacent discs, and endplates were analyzed. Results . Compared with intact status, ACDF with the new prothesis and traditional titanium plate reduced the ROM of C5-6 in six directions by 95.2%-100% and increased that of adjacent discs (C4-5 and C6-7) by 4.8%-112.5%. Adjacent disc stress peaks were higher for the traditional titanium plate (0.7-4.2 MPa) than for the new prosthesis (0.6-4.1 MPa). Endplate stress peaks were the highest in ACDF with the new prosthesis (15.6-53.3 MPa), followed by ACDF with traditional titanium plate (5.0-29.4 MPa). Stress peaks were significantly lower for the new prothesis (12.8-52.3 MPa) than for the traditional titanium plate (397.0-666.1 MPa). Conclusions . The new prosthesis improved the immediate stability of the surgical site and had an elastic modulus that was smaller than that of traditional titanium plate, making it conducive to reducing stress shielding and the impact on the adjacent intervertebral disc. … (more)
- Is Part Of:
- BioMed research international. Volume 2020(2020)
- Journal:
- BioMed research international
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-07-17
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2020/5769293 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14299.xml