Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery. (27th April 2020)
- Record Type:
- Journal Article
- Title:
- Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery. (27th April 2020)
- Main Title:
- Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery
- Authors:
- Wei, Pinghui
Cheng, George PM
Zhang, Jiamei
Ng, Alex LK
Chan, Tommy CY
Jhanji, Vishal
Wang, Yan - Other Names:
- Han Sang Beom Guest Editor.
- Abstract:
- Abstract : Purpose . To investigate the variations of corneal volume (CV) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and analyze the influences of biomechanical properties on the changes of refraction and CV. Methods . Ninety-seven eyes of 97 patients undergoing SMILE and FS-LASIK were included in this retrospective study. CV was measured with Scheimpflug-based corneal topography at preoperatively and at day 1, week 1, and months 1 and 3 postoperatively. CV measured within 5 mm diameter was defined as central region volume (CV5) and between 5 mm and 10 mm diameter was defined as peripheral region volume (CV5-10). An Ocular Response Analyzer (ORA) was used to assess corneal biomechanical properties including corneal hysteresis (CH) and corneal resistant factor (CRF). The reduction of study parameters (△) were calculated by subtracting the preoperative value at various time points from the postoperative values. Results . CV had significant reduction after the SMILE and FS-LASIK procedure (P < 0.05 ). CV5 increased significantly from postoperative day 1 to month 3 (P < 0.001 ) in SMILE, while both CV5 and CV5-10 increased significantly in FS-LASIK (P < 0.001 ). The increase in CV5 after SMILE was 0.11 ± 0.16 mm 3 ,which was significantly different from FS-LASIK (0.20 ± 0.13 mm 3, P = 0.004 ). In the SMILE group, △CV5 correlated with △CRF ( r = 0.498, P < 0.001 ) and △CH ( r = 0.374, P = 0.007 ). InAbstract : Purpose . To investigate the variations of corneal volume (CV) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and analyze the influences of biomechanical properties on the changes of refraction and CV. Methods . Ninety-seven eyes of 97 patients undergoing SMILE and FS-LASIK were included in this retrospective study. CV was measured with Scheimpflug-based corneal topography at preoperatively and at day 1, week 1, and months 1 and 3 postoperatively. CV measured within 5 mm diameter was defined as central region volume (CV5) and between 5 mm and 10 mm diameter was defined as peripheral region volume (CV5-10). An Ocular Response Analyzer (ORA) was used to assess corneal biomechanical properties including corneal hysteresis (CH) and corneal resistant factor (CRF). The reduction of study parameters (△) were calculated by subtracting the preoperative value at various time points from the postoperative values. Results . CV had significant reduction after the SMILE and FS-LASIK procedure (P < 0.05 ). CV5 increased significantly from postoperative day 1 to month 3 (P < 0.001 ) in SMILE, while both CV5 and CV5-10 increased significantly in FS-LASIK (P < 0.001 ). The increase in CV5 after SMILE was 0.11 ± 0.16 mm 3 ,which was significantly different from FS-LASIK (0.20 ± 0.13 mm 3, P = 0.004 ). In the SMILE group, △CV5 correlated with △CRF ( r = 0.498, P < 0.001 ) and △CH ( r = 0.374, P = 0.007 ). In the FS-LASIK group, △CV5 and △CRF had a significant correlation ( r = 0.363, P = 0.012 ), but not with △CH. Conclusions . Dynamic changes in corneal volume were found after SMILE and FS-LASIK surgery. The central region significantly increased after SMILE, while both central and peripheral regions increased following FS-LASIK in the early postoperative period. SMILE was associated with less change in biomechanical properties per unit of reduction in CV compared with FS-LASIK. … (more)
- Is Part Of:
- Journal of ophthalmology. Volume 2020(2020)
- Journal:
- Journal of ophthalmology
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-04-27
- Subjects:
- Ophthalmology -- Periodicals
Eye Diseases
Ophthalmology
Ophthalmology
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
Periodicals
617.7 - Journal URLs:
- https://www.hindawi.com/journals/joph/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1195/ ↗
http://bibpurl.oclc.org/web/46495 ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%229038%22&scope=site ↗ - DOI:
- 10.1155/2020/1713979 ↗
- Languages:
- English
- ISSNs:
- 2090-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14282.xml