Validated Reversed-Phase Ion-Interaction High-Performance Liquid Chromatography for Quantitation of Nitrate Content of Clausena anisata (Willd.) Hook. f. ex Benth. Leaves. (14th March 2020)
- Record Type:
- Journal Article
- Title:
- Validated Reversed-Phase Ion-Interaction High-Performance Liquid Chromatography for Quantitation of Nitrate Content of Clausena anisata (Willd.) Hook. f. ex Benth. Leaves. (14th March 2020)
- Main Title:
- Validated Reversed-Phase Ion-Interaction High-Performance Liquid Chromatography for Quantitation of Nitrate Content of Clausena anisata (Willd.) Hook. f. ex Benth. Leaves
- Authors:
- Monton, Chaowalit
Suksaeree, Jirapornchai
Luprasong, Chitradee - Other Names:
- Erickson Kent L. Academic Editor.
- Abstract:
- Abstract : This work sought to validate the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in the extract and raw material of Clausena anisata (Willd.) Hook. f. ex Benth. leaves. Three extraction methods (i.e., decoction, infusion, and ultrasound-assisted extraction) were investigated and compared. Furthermore, the effect of the solid-to-solvent ratio and defatting was also evaluated. The validation result showed that the high-performance liquid chromatographic method had a linear response ( R 2 = 0.9999) in the range of 1–50 μ g/mL. The limit of detection and limit of quantitation were 0.25 μ g/mL and 0.75 μ g/mL, respectively. In addition, the method was specific, precise, and accurate. So the validated method was suitable for determination of the nitrate content in C. anisata leaves. Infusion of a nondefatted sample using a solid-to-solvent ratio of 1 : 10 gave the highest nitrate content in the raw material, 0.251 ± 0.003%. In case of a defatted sample, decoction provided the highest nitrate content, 0.309 ± 0.001%. Increasing the solid-to-solvent ratio and defatting had a huge effect on the nitrate content of C. anisata leaves extracted from decoction. To the best of our knowledge, this is the first report that used the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in C. anisata leaves. Furthermore, the authors suggested that nitrate could be usedAbstract : This work sought to validate the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in the extract and raw material of Clausena anisata (Willd.) Hook. f. ex Benth. leaves. Three extraction methods (i.e., decoction, infusion, and ultrasound-assisted extraction) were investigated and compared. Furthermore, the effect of the solid-to-solvent ratio and defatting was also evaluated. The validation result showed that the high-performance liquid chromatographic method had a linear response ( R 2 = 0.9999) in the range of 1–50 μ g/mL. The limit of detection and limit of quantitation were 0.25 μ g/mL and 0.75 μ g/mL, respectively. In addition, the method was specific, precise, and accurate. So the validated method was suitable for determination of the nitrate content in C. anisata leaves. Infusion of a nondefatted sample using a solid-to-solvent ratio of 1 : 10 gave the highest nitrate content in the raw material, 0.251 ± 0.003%. In case of a defatted sample, decoction provided the highest nitrate content, 0.309 ± 0.001%. Increasing the solid-to-solvent ratio and defatting had a huge effect on the nitrate content of C. anisata leaves extracted from decoction. To the best of our knowledge, this is the first report that used the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in C. anisata leaves. Furthermore, the authors suggested that nitrate could be used as a standard marker for quality control of C. anisata leaves' extract and raw material. … (more)
- Is Part Of:
- Scientifica. Volume 2020(2020)
- Journal:
- Scientifica
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03-14
- Subjects:
- Life sciences -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biological Science Disciplines
Medicine
Biology
Life sciences
Medicine
Periodicals
Electronic journals
Periodicals
500 - Journal URLs:
- https://www.hindawi.com/journals/scientifica/ ↗
- DOI:
- 10.1155/2020/6424682 ↗
- Languages:
- English
- ISSNs:
- 2090-908X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14286.xml