AMS‐800 Artificial urinary sphincter in female patients with stress urinary incontinence: A systematic review. (9th October 2018)
- Record Type:
- Journal Article
- Title:
- AMS‐800 Artificial urinary sphincter in female patients with stress urinary incontinence: A systematic review. (9th October 2018)
- Main Title:
- AMS‐800 Artificial urinary sphincter in female patients with stress urinary incontinence: A systematic review
- Authors:
- Peyronnet, Benoit
O'Connor, Eabhann
Khavari, Rose
Capon, Grégoire
Manunta, Andrea
Allue, Marta
Hascoet, Juliette
Nitti, Victor W.
Gamé, Xavier
Gilleran, Jason
Castro‐Sader, Luis
Cornu, Jean‐Nicolas
Waltregny, David
Ahyai, Sascha
Chung, Eric
Elliott, Daniel S.
Fournier, Georges
Brucker, Benjamin M. - Abstract:
- Abstract : Aims: To perform a systematic review of studies reporting the outcomes of AMS‐800 artificial urinary sphincter (AUS) implantation in female patients with stress urinary incontinence (SUI) resulting from intrinsic sphincter deficiency (ISD). Methods: A systematic literature search of the Medline and Embase databases was performed in June 2018 in accordance with the PRISMA statement. No time limit was used. The protocol was registered in PROSPERO (CRD42018099612). Study selection and data extraction were performed by two independent reviewers. Results: Of 886 records screened, 17 were included. All were retrospective or prospective non‐comparative case series. One study reported on vaginal AUS implantation, 11 on open AUS implantation, two on laparoscopic AUS implantation, two on robot‐assisted AUS implantation and one compared open and robot‐assisted implantations. The vast majority of patients had undergone at least one anti‐incontinence surgical procedure prior to AUS implantation (69.1‐100%). The intraoperative bladder neck injury rates ranged from 0% to 43.8% and the intraoperative vaginal injury rates ranged from 0 to 25%. After mean follow‐up periods ranging from 5 to 204 months, the complete continence rates ranged from 61.1% to 100%. The rates of explantation, erosion and mechanical failure varied from 0% to 45.3%, 0% to 22.2% and 0% to 44.1%, respectively. Conclusions: AMS‐800 AUS can provide excellent functional outcomes in female patients with SUIAbstract : Aims: To perform a systematic review of studies reporting the outcomes of AMS‐800 artificial urinary sphincter (AUS) implantation in female patients with stress urinary incontinence (SUI) resulting from intrinsic sphincter deficiency (ISD). Methods: A systematic literature search of the Medline and Embase databases was performed in June 2018 in accordance with the PRISMA statement. No time limit was used. The protocol was registered in PROSPERO (CRD42018099612). Study selection and data extraction were performed by two independent reviewers. Results: Of 886 records screened, 17 were included. All were retrospective or prospective non‐comparative case series. One study reported on vaginal AUS implantation, 11 on open AUS implantation, two on laparoscopic AUS implantation, two on robot‐assisted AUS implantation and one compared open and robot‐assisted implantations. The vast majority of patients had undergone at least one anti‐incontinence surgical procedure prior to AUS implantation (69.1‐100%). The intraoperative bladder neck injury rates ranged from 0% to 43.8% and the intraoperative vaginal injury rates ranged from 0 to 25%. After mean follow‐up periods ranging from 5 to 204 months, the complete continence rates ranged from 61.1% to 100%. The rates of explantation, erosion and mechanical failure varied from 0% to 45.3%, 0% to 22.2% and 0% to 44.1%, respectively. Conclusions: AMS‐800 AUS can provide excellent functional outcomes in female patients with SUI resulting from ISD but at the cost of a relatively high morbidity. High level of evidence studies are needed to help better define the role of AUS in the female SUI armamentarium. … (more)
- Is Part Of:
- Neurourology and urodynamics. Volume 38(2019)Supplement 4
- Journal:
- Neurourology and urodynamics
- Issue:
- Volume 38(2019)Supplement 4
- Issue Display:
- Volume 38, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2019-0038-0004-0000
- Page Start:
- S28
- Page End:
- S41
- Publication Date:
- 2018-10-09
- Subjects:
- artificial female urinary incontinence -- stress review -- systematic -- urinary sphincter
Urinary organs -- Periodicals
Urodynamics -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6777 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/nau.23833 ↗
- Languages:
- English
- ISSNs:
- 0733-2467
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.589000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14277.xml