Numerical and experimental investigations on the thermal performance of a data center. (5th November 2020)
- Record Type:
- Journal Article
- Title:
- Numerical and experimental investigations on the thermal performance of a data center. (5th November 2020)
- Main Title:
- Numerical and experimental investigations on the thermal performance of a data center
- Authors:
- Lu, Hongjie
Zhang, Zhongbin - Abstract:
- Highlights: Thermal performance of a data center was studied for various configurations and flow conditions. Raising plenum heights significantly ameliorates the thermal performance. The thermal performance can be improved by decreasing the perforation percentage. Plenum with gradient cross-sections effectively contributes to the air uniformity along the aisle direction. Abstract: Designing an efficient cooling system for a data center can significantly affect its thermal performance. The present paper deals with two kinds of factors that influence the thermal performance of a data center. First the geometry configurations include plenum height (0.4, 0.5, 0.6, and 0.7 m), perforation percentage (10, 20, 30, and 40%) and computer room air conditioning arrangement. Second, the operating parameters include the temperature and volume of air. A total number of 32 configurations have been designed by adjusting the plenum height perforation percentage to investigate the effect of the cooling system arrangement on the overall thermal performance of the data center. The results present a critical range for plenum height (up to 0.6 m) and perforation percentage (higher than 20%) in which the system's thermal performance can be significantly enhanced by adjusting the geometry configurations. Beyond this range, the performance does not change much. Supply air temperature is more related to the thermal performance of the racks near the farther end of the cold aisle. Increasing the supplyHighlights: Thermal performance of a data center was studied for various configurations and flow conditions. Raising plenum heights significantly ameliorates the thermal performance. The thermal performance can be improved by decreasing the perforation percentage. Plenum with gradient cross-sections effectively contributes to the air uniformity along the aisle direction. Abstract: Designing an efficient cooling system for a data center can significantly affect its thermal performance. The present paper deals with two kinds of factors that influence the thermal performance of a data center. First the geometry configurations include plenum height (0.4, 0.5, 0.6, and 0.7 m), perforation percentage (10, 20, 30, and 40%) and computer room air conditioning arrangement. Second, the operating parameters include the temperature and volume of air. A total number of 32 configurations have been designed by adjusting the plenum height perforation percentage to investigate the effect of the cooling system arrangement on the overall thermal performance of the data center. The results present a critical range for plenum height (up to 0.6 m) and perforation percentage (higher than 20%) in which the system's thermal performance can be significantly enhanced by adjusting the geometry configurations. Beyond this range, the performance does not change much. Supply air temperature is more related to the thermal performance of the racks near the farther end of the cold aisle. Increasing the supply air volume can effectively improve the air uniformity along the direction of the cold aisle. Plenum with gradient cross-sections created using inclined partitions significantly reduced the inlet and outlet air temperature by 1.7–2.9 °C. By investigating the effects of geometry configurations and operating parameters on the thermal performance of data centers, the optimal geometry parameters and feasible operating strategy of "high temperature, high air volume" are proposed in this article as the reference and guidance for newly built data centers or retrofitted practices. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 180(2020)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 180(2020)
- Issue Display:
- Volume 180, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 180
- Issue:
- 2020
- Issue Sort Value:
- 2020-0180-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-05
- Subjects:
- Data center -- Thermal performance -- Geometry configuration -- Operating parameters -- Air distribution
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2020.115759 ↗
- Languages:
- English
- ISSNs:
- 1359-4311