Implantable cardioverter‐defibrillators in heart failure patients with reduced ejection fraction and diabetes. (15th May 2018)
- Record Type:
- Journal Article
- Title:
- Implantable cardioverter‐defibrillators in heart failure patients with reduced ejection fraction and diabetes. (15th May 2018)
- Main Title:
- Implantable cardioverter‐defibrillators in heart failure patients with reduced ejection fraction and diabetes
- Authors:
- Sharma, Abhinav
Al‐Khatib, Sana M.
Ezekowitz, Justin A.
Cooper, Lauren B.
Fordyce, Christopher B.
Michael Felker, G.
Bardy, Gust H.
Poole, Jeanne E.
Thomas Bigger, J.
Buxton, Alfred E.
Moss, Arthur J.
Friedman, Daniel J.
Lee, Kerry L.
Steinman, Richard
Dorian, Paul
Cappato, Riccardo
Kadish, Alan H.
Kudenchuk, Peter J.
Mark, Daniel B.
Peterson, Eric D.
Inoue, Lurdes Y.T.
Sanders, Gillian D. - Abstract:
- Abstract : Aim: There is limited information on the outcomes after primary prevention implantable cardioverter‐defibrillator (ICD) implantation in patients with heart failure (HF) and diabetes. This analysis evaluates the effectiveness of a strategy of ICD plus medical therapy vs. medical therapy alone among patients with HF and diabetes. Methods and results: A patient‐level combined‐analysis was conducted from a combined dataset that included four primary prevention ICD trials of patients with HF or severely reduced ejection fractions: Multicenter Automatic Defibrillator Implantation Trial I (MADIT I), MADIT II, Defibrillators in Non‐Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE), and Sudden Cardiac Death in Heart Failure Trial (SCD‐HeFT). In total, 3359 patients were included in the analysis. The primary outcome of interest was all‐cause death. Compared with patients without diabetes ( n = 2363), patients with diabetes ( n = 996) were older and had a higher burden of cardiovascular risk factors. During a median follow‐up of 2.6 years, 437 patients without diabetes died (178 with ICD vs. 259 without) and 280 patients with diabetes died (128 with ICD vs. 152 without). ICDs were associated with a reduced risk of all‐cause mortality among patients without diabetes [hazard ratio (HR) 0.56, 95% confidence interval (CI) 0.46–0.67] but not among patients with diabetes (HR 0.88, 95% CI 0.7–1.12; interaction P = 0.015). Conclusion: Among patients with HF and diabetes,Abstract : Aim: There is limited information on the outcomes after primary prevention implantable cardioverter‐defibrillator (ICD) implantation in patients with heart failure (HF) and diabetes. This analysis evaluates the effectiveness of a strategy of ICD plus medical therapy vs. medical therapy alone among patients with HF and diabetes. Methods and results: A patient‐level combined‐analysis was conducted from a combined dataset that included four primary prevention ICD trials of patients with HF or severely reduced ejection fractions: Multicenter Automatic Defibrillator Implantation Trial I (MADIT I), MADIT II, Defibrillators in Non‐Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE), and Sudden Cardiac Death in Heart Failure Trial (SCD‐HeFT). In total, 3359 patients were included in the analysis. The primary outcome of interest was all‐cause death. Compared with patients without diabetes ( n = 2363), patients with diabetes ( n = 996) were older and had a higher burden of cardiovascular risk factors. During a median follow‐up of 2.6 years, 437 patients without diabetes died (178 with ICD vs. 259 without) and 280 patients with diabetes died (128 with ICD vs. 152 without). ICDs were associated with a reduced risk of all‐cause mortality among patients without diabetes [hazard ratio (HR) 0.56, 95% confidence interval (CI) 0.46–0.67] but not among patients with diabetes (HR 0.88, 95% CI 0.7–1.12; interaction P = 0.015). Conclusion: Among patients with HF and diabetes, primary prevention ICD in combination with medical therapy vs. medical therapy alone was not significantly associated with a reduced risk of all‐cause death. Further studies are needed to evaluate the effectiveness of ICDs among patients with diabetes. … (more)
- Is Part Of:
- European journal of heart failure. Volume 20:Number 6(2018)
- Journal:
- European journal of heart failure
- Issue:
- Volume 20:Number 6(2018)
- Issue Display:
- Volume 20, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 6
- Issue Sort Value:
- 2018-0020-0006-0000
- Page Start:
- 1031
- Page End:
- 1038
- Publication Date:
- 2018-05-15
- Subjects:
- Diabetes -- Implantable cardioverter‐defibrillator -- Comparative effectiveness -- Heart failure -- Competing risk
Heart failure -- Periodicals
Heart Failure -- Periodicals
Insuffisance cardiaque -- Périodiques
Heart failure
Periodicals
616.129005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1879-0844 ↗
http://rave.ohiolink.edu/ejournals/issn/13889842/ ↗
http://www.sciencedirect.com/science/journal/13889842 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ejhf.1192 ↗
- Languages:
- English
- ISSNs:
- 1388-9842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729860
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14259.xml