Enantiomeric separation and quantification of R/S‐amphetamine in serum using semi‐automated liquid‐liquid extraction and ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry. Issue 9 (16th July 2020)
- Record Type:
- Journal Article
- Title:
- Enantiomeric separation and quantification of R/S‐amphetamine in serum using semi‐automated liquid‐liquid extraction and ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry. Issue 9 (16th July 2020)
- Main Title:
- Enantiomeric separation and quantification of R/S‐amphetamine in serum using semi‐automated liquid‐liquid extraction and ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry
- Authors:
- Havnen, Hilde
Hansen, Miriam
Spigset, Olav
Hegstad, Solfrid - Abstract:
- Abstract: The amphetamine molecule contains a chiral center and its enantiomers exhibit differences in pharmacological effects, with the S‐enantiomer mediating most of the central nervous system stimulating activity. The majority of prescribed amphetamine consists of the pure S‐enantiomer, but therapeutic formulations containing the R‐enantiomer in various proportions are also available. Illegal amphetamine remains available mainly as a racemic mixture of the R‐ and S‐enantiomers. To distinguish between legal and illegal consumption of amphetamine a method for enantiomeric separation and quantification of R/S‐amphetamine in serum was developed and validated using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry (UHPSFC‐MS/MS). Sample preparation prior to UHPSFC‐MS/MS analysis was performed by a semi‐automated liquid–liquid extraction method. The UHPSFC‐MS/MS method used a Chiralpak AD‐3 column with a mobile phase consisting of CO2 and 0.1% ammonium hydroxide in 2‐propanol/methanol (50/50, v/v). The injection volume was 2 μL and run time was 4 minutes. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions ( m/z 136.1 > 119.0 and m/z 136.1 > 91.0). The calibration range was 12.5–1, 000 nM for each analyte. The between‐assay relative standard deviations were in the range of 1.3–3.0%. Recovery was 73% and matrix effects ranged from 95 to 100% when corrected with internal standard.Abstract: The amphetamine molecule contains a chiral center and its enantiomers exhibit differences in pharmacological effects, with the S‐enantiomer mediating most of the central nervous system stimulating activity. The majority of prescribed amphetamine consists of the pure S‐enantiomer, but therapeutic formulations containing the R‐enantiomer in various proportions are also available. Illegal amphetamine remains available mainly as a racemic mixture of the R‐ and S‐enantiomers. To distinguish between legal and illegal consumption of amphetamine a method for enantiomeric separation and quantification of R/S‐amphetamine in serum was developed and validated using ultra‐high performance supercritical fluid chromatography‐tandem mass spectrometry (UHPSFC‐MS/MS). Sample preparation prior to UHPSFC‐MS/MS analysis was performed by a semi‐automated liquid–liquid extraction method. The UHPSFC‐MS/MS method used a Chiralpak AD‐3 column with a mobile phase consisting of CO2 and 0.1% ammonium hydroxide in 2‐propanol/methanol (50/50, v/v). The injection volume was 2 μL and run time was 4 minutes. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions ( m/z 136.1 > 119.0 and m/z 136.1 > 91.0). The calibration range was 12.5–1, 000 nM for each analyte. The between‐assay relative standard deviations were in the range of 1.3–3.0%. Recovery was 73% and matrix effects ranged from 95 to 100% when corrected with internal standard. After development and validation, the method has been successfully implemented in our laboratory for both separation and quantification of R/S‐amphetamine and has proved to be a reliable and useful tool for distinguishing intake of R‐ and S‐amphetamine in authentic patient samples. Abstract : A validated high throughput UHPSFC‐MS/MS method for enantioselective quantification of R/S‐amphetamine in serum is presented. The method applies semi‐automated liquid–liquid extraction for sample preparation and an analytical runtime of 4 minutes. It has proved to be a reliable and useful tool for distinguishing intake of R‐ and S‐amphetamine in patient samples. … (more)
- Is Part Of:
- Drug testing and analysis. Volume 12:Issue 9(2020)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 12:Issue 9(2020)
- Issue Display:
- Volume 12, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 9
- Issue Sort Value:
- 2020-0012-0009-0000
- Page Start:
- 1344
- Page End:
- 1353
- Publication Date:
- 2020-07-16
- Subjects:
- drugs of abuse -- R/S‐amphetamine -- serum -- therapeutic drug monitoring -- UHPSFC‐MS/MS
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.2879 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14265.xml