Implications of hydrodynamic testing to guide sizing of self‐expanding transcatheter heart valves for valve‐in‐valve procedures. Issue 3 (24th October 2019)
- Record Type:
- Journal Article
- Title:
- Implications of hydrodynamic testing to guide sizing of self‐expanding transcatheter heart valves for valve‐in‐valve procedures. Issue 3 (24th October 2019)
- Main Title:
- Implications of hydrodynamic testing to guide sizing of self‐expanding transcatheter heart valves for valve‐in‐valve procedures
- Authors:
- Sathananthan, Janarthanan
Hensey, Mark
Fraser, Rob
Landes, Uri
Blanke, Philipp
Hatoum, Hoda
Dasi, Lakshmi Prasad
Sedaghat, Alexander
Bapat, Vinayak N
Leipsic, Jonathon
Søndergaard, Lars
Wood, David A.
Webb, John G. - Abstract:
- Abstract: Aims: The commonly used valve‐in‐valve (VIV) app recommends sizing based on dimensions of both the transcatheter heart valve (THV) and bioprosthetic surgical valve. The implications of hydrodynamic testing to guide VIV sizing are poorly understood. This bench study assessed the hydrodynamic performance of different sizes of self‐expanding supra‐annular THVs in three different surgical aortic bioprostheses at different implantation depths. Methods: A small versus medium ACURATE neo (ACn), and a 26 mm versus 29 mm Evolut R were assessed after VIV implantation in 25 mm Mitroflow, Mosaic, and Magna Ease aortic surgical bioprostheses, at three implantation depths (+2 mm, ‐2 mm, and ‐6 mm). Results: The medium‐sized ACn had lower gradients compared to the small ACn when the THV was implanted high (+2 mm, or ‐2 mm). The 29 mm Evolut R had lower gradients compared to a 26 mm Evolut R for all implantation depths, except for a depth of ‐2 mm in the 25 mm Mitroflow. The medium ACn and 29 mm Evolut R had larger effective orifice areas compared to the small ACn and 26 mm Evolut R, respectively. Both Evolut R sizes had acceptable regurgitant fractions (<15%), while both ACn sizes were above the acceptable performance criteria (>15%), at all implantation depths. Conclusions: Use of a larger self‐expanding THV was associated with superior hydrodynamic performance if the THV was implanted high. Hydrodynamic testing can provide additional information to the VIV app to help guide VIVAbstract: Aims: The commonly used valve‐in‐valve (VIV) app recommends sizing based on dimensions of both the transcatheter heart valve (THV) and bioprosthetic surgical valve. The implications of hydrodynamic testing to guide VIV sizing are poorly understood. This bench study assessed the hydrodynamic performance of different sizes of self‐expanding supra‐annular THVs in three different surgical aortic bioprostheses at different implantation depths. Methods: A small versus medium ACURATE neo (ACn), and a 26 mm versus 29 mm Evolut R were assessed after VIV implantation in 25 mm Mitroflow, Mosaic, and Magna Ease aortic surgical bioprostheses, at three implantation depths (+2 mm, ‐2 mm, and ‐6 mm). Results: The medium‐sized ACn had lower gradients compared to the small ACn when the THV was implanted high (+2 mm, or ‐2 mm). The 29 mm Evolut R had lower gradients compared to a 26 mm Evolut R for all implantation depths, except for a depth of ‐2 mm in the 25 mm Mitroflow. The medium ACn and 29 mm Evolut R had larger effective orifice areas compared to the small ACn and 26 mm Evolut R, respectively. Both Evolut R sizes had acceptable regurgitant fractions (<15%), while both ACn sizes were above the acceptable performance criteria (>15%), at all implantation depths. Conclusions: Use of a larger self‐expanding THV was associated with superior hydrodynamic performance if the THV was implanted high. Hydrodynamic testing can provide additional information to the VIV app to help guide VIV sizing. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 96:Issue 3(2020)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 96:Issue 3(2020)
- Issue Display:
- Volume 96, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 96
- Issue:
- 3
- Issue Sort Value:
- 2020-0096-0003-0000
- Page Start:
- E332
- Page End:
- E340
- Publication Date:
- 2019-10-24
- Subjects:
- ACURATE neo -- hydrodynamic performance -- self‐expanding -- transcatheter heart valve -- valve‐in‐valve
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28537 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14263.xml