Diffusion-weighted magnetic resonance imaging is more sensitive than dimercaptosuccinic acid scintigraphy in detecting parenchymal lesions in children with acute pyelonephritis: A prospective study. Issue 3 (June 2018)
- Record Type:
- Journal Article
- Title:
- Diffusion-weighted magnetic resonance imaging is more sensitive than dimercaptosuccinic acid scintigraphy in detecting parenchymal lesions in children with acute pyelonephritis: A prospective study. Issue 3 (June 2018)
- Main Title:
- Diffusion-weighted magnetic resonance imaging is more sensitive than dimercaptosuccinic acid scintigraphy in detecting parenchymal lesions in children with acute pyelonephritis: A prospective study
- Authors:
- Bosakova, Alice
Salounova, Dana
Havelka, Jaroslav
Kraft, Otakar
Sirucek, Pavel
Kocvara, Radim
Hladik, Michal - Abstract:
- Summary: Introduction: Static renal scintigraphy is the gold standard for detection of inflammatory changes in the renal parenchyma in acute pyelonephritis. Our aim was to determine whether diffusion-weighted magnetic resonance imaging (DW-MRI) was comparable with static renal scintigraphy (DMSA-SRS) to demonstrate acute renal parenchymal lesions. Objective: To compare 99m Tc-dimercaptosuccinic acid static renal scintigraphy (DMSA-SRS) with diffusion-weighted magnetic resonance imaging (DW-MRI) for detecting acute inflammatory changes in the renal parenchyma in children with febrile urinary tract infection. Methods: Thirty-one children (30 girls) aged 3–18 years with a first episode of febrile UTI without a previously detected congenital malformation of the urinary tract, were prospectively included. DMSA-SRS and DW-MRI were performed within 5 days of diagnosis to detect renal inflammatory lesions. The DW-MRI examination was performed without contrast agent and without general anesthesia. Late examinations were performed after 6 months using both methods to detect late lesions. Results: DW-MRI confirmed acute inflammatory changes of the renal parenchyma in all 31 patients (100%), mostly unilateral. DMSA-SRS detected inflammatory lesions in 22 children (71%; p = 0.002). The lesions were multiple in 26/31 children (84%) on DW-MRI and in 9/22 (40%) on DMSA-SRS. At the control examination, scarring of the renal parenchyma was found equally by DW-MRI and DMSA-SRS in fiveSummary: Introduction: Static renal scintigraphy is the gold standard for detection of inflammatory changes in the renal parenchyma in acute pyelonephritis. Our aim was to determine whether diffusion-weighted magnetic resonance imaging (DW-MRI) was comparable with static renal scintigraphy (DMSA-SRS) to demonstrate acute renal parenchymal lesions. Objective: To compare 99m Tc-dimercaptosuccinic acid static renal scintigraphy (DMSA-SRS) with diffusion-weighted magnetic resonance imaging (DW-MRI) for detecting acute inflammatory changes in the renal parenchyma in children with febrile urinary tract infection. Methods: Thirty-one children (30 girls) aged 3–18 years with a first episode of febrile UTI without a previously detected congenital malformation of the urinary tract, were prospectively included. DMSA-SRS and DW-MRI were performed within 5 days of diagnosis to detect renal inflammatory lesions. The DW-MRI examination was performed without contrast agent and without general anesthesia. Late examinations were performed after 6 months using both methods to detect late lesions. Results: DW-MRI confirmed acute inflammatory changes of the renal parenchyma in all 31 patients (100%), mostly unilateral. DMSA-SRS detected inflammatory lesions in 22 children (71%; p = 0.002). The lesions were multiple in 26/31 children (84%) on DW-MRI and in 9/22 (40%) on DMSA-SRS. At the control examination, scarring of the renal parenchyma was found equally by DW-MRI and DMSA-SRS in five patients (16%), three of whom were the same patients. The overall concordance of positive and negative late findings occurred in 87% of patients. There was correspondence in the anatomical location of acute and late lesions. Discussion: The clinical significance of acute and late parenchymal findings on DWI-MR is yet to be determined. A limitation of our study is the age of the patients (older than 3 years) who are less sensitive to scar development; therefore, a smaller number of patients with scars could be analyzed during control examination. Further studies using the DW-MRI should confirm its reliability to detect acute and late lesions in younger children and infants and determine the clinical consequences. Conclusion: DW-MRI has higher sensitivity for detecting acute renal inflammatory lesions and multifocal lesions than DMSA-SRS. The incidence of scars was low and corresponded with the anatomical location of acute and late lesions. Fig Acute inflammatory changes in the right kidney on DMSA-SRS (A) and DW-MRI (B) in our study. … (more)
- Is Part Of:
- Journal of pediatric urology. Volume 14:Issue 3(2018)
- Journal:
- Journal of pediatric urology
- Issue:
- Volume 14:Issue 3(2018)
- Issue Display:
- Volume 14, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 14
- Issue:
- 3
- Issue Sort Value:
- 2018-0014-0003-0000
- Page Start:
- 269.e1
- Page End:
- 269.e7
- Publication Date:
- 2018-06
- Subjects:
- Acute pyelonephritis -- Diffusion-weighted magnetic resonance imaging (DW-MRI) -- 99mTc DMSA renal scintigraphy
Pediatric urology -- Periodicals
Urologic Diseases -- Periodicals
Urogenital Diseases -- Periodicals
Urologic Surgical Procedures -- Periodicals
Child
Infant
Urologie pédiatrique -- Périodiques
Appareil urinaire -- Maladies -- Périodiques
Pédiatrie
Urologie
Pediatric urology
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
Electronic journals
Periodicals
Electronic journals
618.926 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14775131 ↗
http://www.sciencedirect.com/science/journal/14775131 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpurol.2018.02.014 ↗
- Languages:
- English
- ISSNs:
- 1477-5131
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14240.xml