Iris suture fixation of out‐of‐the‐bag dislocated three‐piece intraocular lenses. Issue 6 (7th February 2019)
- Record Type:
- Journal Article
- Title:
- Iris suture fixation of out‐of‐the‐bag dislocated three‐piece intraocular lenses. Issue 6 (7th February 2019)
- Main Title:
- Iris suture fixation of out‐of‐the‐bag dislocated three‐piece intraocular lenses
- Authors:
- Armonaite, Laura
Löfgren, Stefan
Behndig, Anders - Abstract:
- Abstract: Purpose: To evaluate the efficacy and safety of iris suture fixation of out‐of‐the‐bag dislocated three‐piece intraocular lenses (IOL). Methods: In a retrospective interventional consecutive case series, a chart review was performed in two groups of patients: fourteen patients with a dislocated out‐of‐the‐bag three‐piece IOL that underwent IOL fixation to the iris using the Siepser sliding knot technique (Iris group) and 18 patients with in‐the‐bag dislocation that underwent IOL exchange with a new scleral‐sutured IOL (Exchange group). The Iris and Exchange groups were compared regarding surgical safety and efficacy. The median follow‐up time was 13.5 months [interquartile range (IQR), 10–20] in the Iris group and 12.5 (IQR, 10–14) in the Exchange group. Results: The best corrected visual acuity (BCVA) improved significantly in both groups (p = 0.005 and 0.00006, respectively). No difference in final BCVA was seen between the groups. Significantly less surgically induced astigmatism (p = 0.03) and a lower number of postoperative visits (p = 0.0006) was noted in the Iris group. Considering the type of surgery, there were few complications in the present material. Conclusion: In the study, suturing dislocated three‐piece IOLs to the iris appeared to be an acceptable surgical management with less surgically induced corneal astigmatism and fewer postoperative visits than IOL exchange. A larger study with a longer follow‐up time would be desirable to confirm the results.
- Is Part Of:
- Acta ophthalmologica. Volume 97:Issue 6(2019)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 97:Issue 6(2019)
- Issue Display:
- Volume 97, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 97
- Issue:
- 6
- Issue Sort Value:
- 2019-0097-0006-0000
- Page Start:
- 583
- Page End:
- 588
- Publication Date:
- 2019-02-07
- Subjects:
- intraocular lens exchange -- iris fixation -- out‐of‐the‐bag dislocated intraocular lenses -- Siepser sliding knot
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.14059 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14247.xml