A systematic evaluation of the error detection abilities of a new diode transmission detector. Issue 9 (5th August 2019)
- Record Type:
- Journal Article
- Title:
- A systematic evaluation of the error detection abilities of a new diode transmission detector. Issue 9 (5th August 2019)
- Main Title:
- A systematic evaluation of the error detection abilities of a new diode transmission detector
- Authors:
- Sarkar, Vikren
Paxton, Adam
Kunz, Jeremy
Szegedi, Martin
Nelson, Geoff
Rassiah‐Szegedi, Prema
Zhao, Hui
Huang, Y. Jessica
Su, Frances
Salter, Bill J. - Abstract:
- Abstract: Transmission detectors meant to measure every beam delivered on a linear accelerator are now becoming available for monitoring the quality of the dose distribution delivered to the patient daily. The purpose of this work is to present results from a systematic evaluation of the error detection capabilities of one such detector, the Delta 4 Discover. Existing patient treatment plans were modified through in‐house‐developed software to mimic various delivery errors that have been observed in the past. Errors included shifts in multileaf collimator leaf positions, changing the beam energy from what was planned, and a simulation of what would happen if the secondary collimator jaws did not track with the leaves as they moved. The study was done for simple 3D plans, static gantry intensity modulated radiation therapy plans as well as dynamic arc and volumetric modulated arc therapy (VMAT) plans. Baseline plans were delivered with both the Discover device and the Delta 4 Phantom+ to establish baseline gamma pass rates. Modified plans were then delivered using the Discover only and the predicted change in gamma pass rate, as well as the detected leaf positions were evaluated. Leaf deviations as small as 0.5 mm for a static three‐dimensional field were detected, with this detection limit growing to 1 mm with more complex delivery modalities such as VMAT. The gamma pass rates dropped noticeably once the intentional leaf error introduced was greater than theAbstract: Transmission detectors meant to measure every beam delivered on a linear accelerator are now becoming available for monitoring the quality of the dose distribution delivered to the patient daily. The purpose of this work is to present results from a systematic evaluation of the error detection capabilities of one such detector, the Delta 4 Discover. Existing patient treatment plans were modified through in‐house‐developed software to mimic various delivery errors that have been observed in the past. Errors included shifts in multileaf collimator leaf positions, changing the beam energy from what was planned, and a simulation of what would happen if the secondary collimator jaws did not track with the leaves as they moved. The study was done for simple 3D plans, static gantry intensity modulated radiation therapy plans as well as dynamic arc and volumetric modulated arc therapy (VMAT) plans. Baseline plans were delivered with both the Discover device and the Delta 4 Phantom+ to establish baseline gamma pass rates. Modified plans were then delivered using the Discover only and the predicted change in gamma pass rate, as well as the detected leaf positions were evaluated. Leaf deviations as small as 0.5 mm for a static three‐dimensional field were detected, with this detection limit growing to 1 mm with more complex delivery modalities such as VMAT. The gamma pass rates dropped noticeably once the intentional leaf error introduced was greater than the distance‐to‐agreement criterion. The unit also demonstrated the desired drop in gamma pass rates of at least 20% when jaw tracking was intentionally disabled and when an incorrect energy was used for the delivery. With its ability to find errors intentionally introduced into delivered plans, the Discover shows promise of being a valuable, independent error detection tool that should serve to detect delivery errors that can occur during radiotherapy treatment. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 9(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 9(2019)
- Issue Display:
- Volume 20, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 9
- Issue Sort Value:
- 2019-0020-0009-0000
- Page Start:
- 122
- Page End:
- 132
- Publication Date:
- 2019-08-05
- Subjects:
- error detection -- IMRT -- quality assurance -- transmission detector
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12691 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14237.xml