Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy. Issue 9 (3rd September 2019)
- Record Type:
- Journal Article
- Title:
- Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy. Issue 9 (3rd September 2019)
- Main Title:
- Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy
- Authors:
- Kügele, Malin
Mannerberg, Annika
Nørring Bekke, Susanne
Alkner, Sara
Berg, Lovisa
Mahmood, Faisal
Thornberg, Charlotte
Edvardsson, Anneli
Bäck, Sven Å. J.
Behrens, Claus F.
Ceberg, Sofie - Abstract:
- Abstract: Purpose: The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser‐based setup (LBS). Materials and Methods: Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). Results: For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS ( P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. Conclusions: Conventional laser‐based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patientsAbstract: Purpose: The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser‐based setup (LBS). Materials and Methods: Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). Results: For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS ( P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. Conclusions: Conventional laser‐based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patients regardless if a single or three camera system was used. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 9(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 9(2019)
- Issue Display:
- Volume 20, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 9
- Issue Sort Value:
- 2019-0020-0009-0000
- Page Start:
- 61
- Page End:
- 68
- Publication Date:
- 2019-09-03
- Subjects:
- interfraction motion -- optical surface scanning -- patient positioning -- surface guided radiotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12700 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14237.xml