- Feasibility of transient elastography versus real-time two-dimensional shear wave elastography in difficult-to-scan patients. (1st November 2016)
- Main Title:
- Feasibility of transient elastography versus real-time two-dimensional shear wave elastography in difficult-to-scan patients
- Authors:
- Staugaard, Benjamin
Christensen, Peer Brehm
Mössner, Belinda
Hansen, Janne Fuglsang
Madsen, Bjørn Stæhr
Søholm, Jacob
Krag, Aleksander
Thiele, Maja - Abstract:
- Abstract: Background and aims: Transient elastography (TE) is hampered in some patients by failures and unreliable results. We hypothesized that real time two-dimensional shear wave elastography (2D-SWE), the FibroScan XL probe, and repeated TE exams, could be used to obtain reliable liver stiffness measurements in patients with an invalid TE examination. Methods: We reviewed 1975 patients with 5764 TE exams performed between 2007 and 2014, to identify failures and unreliable exams. Fifty-four patients with an invalid TE at their latest appointment entered a comparative feasibility study of TE vs. 2D-SWE. Results: The initial TE exam was successful in 93% (1835/1975) of patients. Success rate increased from 89% to 96% when the XL probe became available (OR: 1.07, 95% CI 1.06–1.09). Likewise, re-examining those with a failed or unreliable TE led to a reliable TE in 96% of patients. Combining availability of the XL probe with TE re-examination resulted in a 99.5% success rate on a per-patient level. When comparing the feasibility of TE vs. 2D-SWE, 96% (52/54) of patients obtained a reliable TE, while 2D-SWE was reliable in 63% (34/54, p < 0.001). The odds of a successful 2D-SWE exam decreased with higher skin-capsule distance (OR = 0.77, 95% CI 0.67–0.98). Conclusions: Transient elastography can be accomplished in nearly all patients by use of the FibroScan XL probe and repeated examinations. In difficult-to-scan patients, the feasibility of TE is superior to 2D-SWE.
- Is Part Of:
- Scandinavian journal of gastroenterology. Volume 51:Number 11(2016)
- Journal:
- Scandinavian journal of gastroenterology
- Issue:
- Volume 51:Number 11(2016)
- Issue Display:
- Volume 51, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 51
- Issue:
- 11
- Issue Sort Value:
- 2016-0051-0011-0000
- Page Start:
- 1354
- Page End:
- 1359
- Publication Date:
- 2016-11-01
- Subjects:
- Aixplorer -- applicability -- failure rate -- liver fibrosis -- obesity -- supersonic shear imaging
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33 - Journal URLs:
- http://informahealthcare.com/loi/gas ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365521.2016.1193217 ↗
- Languages:
- English
- ISSNs:
- 0036-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.507000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14241.xml