Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty in the Treatment of Failed Penetrating Keratoplasty. Issue 9 (September 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty in the Treatment of Failed Penetrating Keratoplasty. Issue 9 (September 2019)
- Main Title:
- Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty in the Treatment of Failed Penetrating Keratoplasty
- Authors:
- Einan-Lifshitz, Adi
Mednick, Zale
Belkin, Avner
Sorkin, Nir
Alshaker, Sara
Boutin, Tanguy
Chan, Clara C.
Rootman, David S. - Abstract:
- Abstract : Purpose: To compare the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) with Descemet membrane endothelial keratoplasty (DMEK) for the treatment of failed penetrating keratoplasty (PKP). Methods: This is a retrospective chart review of patients with failed PKP who underwent DMEK or DSAEK. The median follow-up time for both groups was 28 months (range 6–116 months). Data collection included demographic characteristics, number of previous corneal transplants, previous glaucoma surgeries, best-corrected visual acuity, endothelial cell density, graft detachment and rebubble rate, rejection episodes, and graft failure. Results: Twenty-eight eyes in the DMEK group and 24 eyes in the DSAEK group were included in the analysis. Forty-three percent of eyes in the DMEK group and 50% of eyes in the DSAEK group had to be regrafted because of failure ( P = 0.80). The most common reason for failure was persistent graft detachment (58%) in the DMEK group and secondary failure (58%) in the DSAEK group; hence, the time between endothelial keratoplasty and graft failure differed significantly between the groups ( P = 0.02). Six eyes (21%) in the DMEK group and 7 eyes (29%) in the DSAEK group developed graft rejection ( P = 0.39). Rejection was the cause of failure in 67% and 71% in the DMEK and DSAEK groups, respectively. The best-corrected visual acuity 6 months after surgery was better in the DMEK group compared with the DSAEK group ( P = 0.051).Abstract : Purpose: To compare the outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) with Descemet membrane endothelial keratoplasty (DMEK) for the treatment of failed penetrating keratoplasty (PKP). Methods: This is a retrospective chart review of patients with failed PKP who underwent DMEK or DSAEK. The median follow-up time for both groups was 28 months (range 6–116 months). Data collection included demographic characteristics, number of previous corneal transplants, previous glaucoma surgeries, best-corrected visual acuity, endothelial cell density, graft detachment and rebubble rate, rejection episodes, and graft failure. Results: Twenty-eight eyes in the DMEK group and 24 eyes in the DSAEK group were included in the analysis. Forty-three percent of eyes in the DMEK group and 50% of eyes in the DSAEK group had to be regrafted because of failure ( P = 0.80). The most common reason for failure was persistent graft detachment (58%) in the DMEK group and secondary failure (58%) in the DSAEK group; hence, the time between endothelial keratoplasty and graft failure differed significantly between the groups ( P = 0.02). Six eyes (21%) in the DMEK group and 7 eyes (29%) in the DSAEK group developed graft rejection ( P = 0.39). Rejection was the cause of failure in 67% and 71% in the DMEK and DSAEK groups, respectively. The best-corrected visual acuity 6 months after surgery was better in the DMEK group compared with the DSAEK group ( P = 0.051). Conclusions: Both DSAEK and DMEK have a role in treating PKP failure. Primary failure due to persistent graft detachment was significantly higher in the DMEK group, although the overall failure rate in the medium term was similar. … (more)
- Is Part Of:
- Cornea. Volume 38:Issue 9(2019)
- Journal:
- Cornea
- Issue:
- Volume 38:Issue 9(2019)
- Issue Display:
- Volume 38, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2019-0038-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- DSAEK -- DMEK -- PKP -- failed graft
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000001993 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14218.xml