A New and More Sensitive View for the Detection of Syndesmotic Instability. Issue 9 (September 2019)
- Record Type:
- Journal Article
- Title:
- A New and More Sensitive View for the Detection of Syndesmotic Instability. Issue 9 (September 2019)
- Main Title:
- A New and More Sensitive View for the Detection of Syndesmotic Instability
- Authors:
- Gosselin-Papadopoulos, Nayla
Hébert-Davies, Jonah
Laflamme, Georges-Yves
Ménard, Jérémie
Leduc, Stéphane
Nault, Marie-Lyne - Abstract:
- Abstract : Objectives: We hypothesize that a single syndesmotic view, capturing both sagittal and coronal tibiofibular displacement, will be more sensitive than a mortise view to detect syndesmotic instability. Methods: Ten fresh frozen human lower limbs were used to test the new syndesmotic view with simulated syndesmosis injury. The anteroinferior tibiofibular ligament, interosseous membrane, and posteroinferior tibiofibular ligament were sectioned sequentially. At each stage, the syndesmosis was tested using the external rotation stress (ERS) test and lateral stress test (LST). For each stress condition, a true mortise view and the new syndesmotic view were performed. Medial clear space and tibiofibular clear space (TFCS) were measured on a mortise view, and TFCS was measured on a syndesmotic view (TFCS-s). Wilcoxon signed-rank tests were used to compare measurements. Results: Syndesmotic view enabled instability detection with a 2-ligament dissection at a mean increase in TFCS-s of 2.37 mm ( P = 0.021) and 1.98 mm ( P = 0.011), using the ERS and LST, respectively. TFCS on the mortise view was significantly different only with a complete injury. Medial clear space did not vary significantly with injury increments. Sensitivity was 66% and 61% using ERS and LST, respectively, for the TFCS-s, compared with 27% and 33%, respectively, for the TFCS. Specificity was similar for TFCS and TFCS-s. Conclusions: This study was able to demonstrate that the syndesmotic view is moreAbstract : Objectives: We hypothesize that a single syndesmotic view, capturing both sagittal and coronal tibiofibular displacement, will be more sensitive than a mortise view to detect syndesmotic instability. Methods: Ten fresh frozen human lower limbs were used to test the new syndesmotic view with simulated syndesmosis injury. The anteroinferior tibiofibular ligament, interosseous membrane, and posteroinferior tibiofibular ligament were sectioned sequentially. At each stage, the syndesmosis was tested using the external rotation stress (ERS) test and lateral stress test (LST). For each stress condition, a true mortise view and the new syndesmotic view were performed. Medial clear space and tibiofibular clear space (TFCS) were measured on a mortise view, and TFCS was measured on a syndesmotic view (TFCS-s). Wilcoxon signed-rank tests were used to compare measurements. Results: Syndesmotic view enabled instability detection with a 2-ligament dissection at a mean increase in TFCS-s of 2.37 mm ( P = 0.021) and 1.98 mm ( P = 0.011), using the ERS and LST, respectively. TFCS on the mortise view was significantly different only with a complete injury. Medial clear space did not vary significantly with injury increments. Sensitivity was 66% and 61% using ERS and LST, respectively, for the TFCS-s, compared with 27% and 33%, respectively, for the TFCS. Specificity was similar for TFCS and TFCS-s. Conclusions: This study was able to demonstrate that the syndesmotic view is more sensitive than the mortise view in detecting syndesmotic instability in a cadaveric model. It is particularly helpful to uncover instability secondary to an incomplete syndesmosis injury requiring fixation. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 33:Issue 9(2019)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 33:Issue 9(2019)
- Issue Display:
- Volume 33, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 9
- Issue Sort Value:
- 2019-0033-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- imaging -- syndesmotic injury -- syndesmosis -- diagnostic test
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001495 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14221.xml