AcidoCEST-UTE MRI for the Assessment of Extracellular pH of Joint Tissues at 3 T. Issue 9 (September 2019)
- Record Type:
- Journal Article
- Title:
- AcidoCEST-UTE MRI for the Assessment of Extracellular pH of Joint Tissues at 3 T. Issue 9 (September 2019)
- Main Title:
- AcidoCEST-UTE MRI for the Assessment of Extracellular pH of Joint Tissues at 3 T
- Authors:
- Ma, Ya-Jun
High, Rachel A.
Tang, Qingbo
Wan, Lidi
Jerban, Saeed
Du, Jiang
Chang, Eric Y. - Abstract:
- Abstract : Objectives: The goal of this study was to demonstrate feasibility of measuring extracellular pH in cartilage and meniscus using acidoCEST technique with a 3-dimensional ultrashort echo time readout (acidoCEST-UTE) magnetic resonance imaging (MRI). Materials and Methods: Magnetization transfer ratio asymmetry, radiofrequency (RF) power mismatch, and relative saturation transfer were evaluated in liquid phantoms for iopromide, iopamidol, and iohexol over a pH range of 6.2 to 7.8, at various agent concentrations, temperatures, and buffer concentrations. Tissue phantoms containing cartilage and meniscus were evaluated with the same considerations for iopamidol and iohexol. Phantoms were imaged with the acidoCEST-UTE MRI sequence at 3 T. Correlation coefficients and coefficients of variations were calculated. Paired Wilcoxon rank-sum tests were used to evaluate for statistically significant differences. Results: The RF power mismatch and relative saturation transfer analyses of liquid phantoms showed iopamidol and iohexol to be the most promising agents for this study. Both these agents appeared to be concentration independent and feasible for use with or without buffer and at physiologic temperature over a pH range of 6.2 to 7.8. Ultimately, RF power mismatch fitting of iohexol showed the strongest correlation coefficients between cartilage, meniscus, and fluid. In addition, ratiometric values for iohexol are similar among liquid as well as different tissue types.Abstract : Objectives: The goal of this study was to demonstrate feasibility of measuring extracellular pH in cartilage and meniscus using acidoCEST technique with a 3-dimensional ultrashort echo time readout (acidoCEST-UTE) magnetic resonance imaging (MRI). Materials and Methods: Magnetization transfer ratio asymmetry, radiofrequency (RF) power mismatch, and relative saturation transfer were evaluated in liquid phantoms for iopromide, iopamidol, and iohexol over a pH range of 6.2 to 7.8, at various agent concentrations, temperatures, and buffer concentrations. Tissue phantoms containing cartilage and meniscus were evaluated with the same considerations for iopamidol and iohexol. Phantoms were imaged with the acidoCEST-UTE MRI sequence at 3 T. Correlation coefficients and coefficients of variations were calculated. Paired Wilcoxon rank-sum tests were used to evaluate for statistically significant differences. Results: The RF power mismatch and relative saturation transfer analyses of liquid phantoms showed iopamidol and iohexol to be the most promising agents for this study. Both these agents appeared to be concentration independent and feasible for use with or without buffer and at physiologic temperature over a pH range of 6.2 to 7.8. Ultimately, RF power mismatch fitting of iohexol showed the strongest correlation coefficients between cartilage, meniscus, and fluid. In addition, ratiometric values for iohexol are similar among liquid as well as different tissue types. Conclusions: Measuring extracellular pH in cartilage and meniscus using acidoCEST-UTE MRI is feasible. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Investigative radiology. Volume 54:Issue 9(2019)
- Journal:
- Investigative radiology
- Issue:
- Volume 54:Issue 9(2019)
- Issue Display:
- Volume 54, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 54
- Issue:
- 9
- Issue Sort Value:
- 2019-0054-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- MRI -- chemical exchange saturation transfer -- pH -- osteoarthritis -- acidoCEST
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000576 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14205.xml