Prediction of Best-Corrected Visual Acuity With Swept-Source Optical Coherence Tomography Parameters in Keratoconus. Issue 9 (September 2019)
- Record Type:
- Journal Article
- Title:
- Prediction of Best-Corrected Visual Acuity With Swept-Source Optical Coherence Tomography Parameters in Keratoconus. Issue 9 (September 2019)
- Main Title:
- Prediction of Best-Corrected Visual Acuity With Swept-Source Optical Coherence Tomography Parameters in Keratoconus
- Authors:
- Esaka, Yuri
Kojima, Takashi
Dogru, Murat
Hasegawa, Asato
Tamaoki, Akeno
Uno, Yunako
Nishida, Tomoya
Nakamura, Tomoaki
Hara, Syuya
Ichikawa, Kazuo - Abstract:
- Abstract : Purpose: This study aimed to predict the best-corrected visual acuity (BCVA) based on swept-source optical coherence tomography (SS-OCT) parameters in eyes with keratoconus. Methods: We retrospectively reviewed 135 eyes of 135 patients with keratoconus (mean age: 31.9 ± 12.4 years). The average keratometry value and BCVA (logarithm of the minimal angle of resolution [Snellen]) were 48.68 ± 5.44 diopter and 0.20 ± 0.36 (20/25), respectively. Eleven parameters were calculated using SS-OCT. Apart from the corneal height and elevation, all the other parameters were calculated from both anterior and posterior corneal OCT data. The patients were divided into 2 groups, 1 for creating the prediction equation (prediction group, 86 eyes) and another for verifying the equation (verification group, 49 eyes). In the former, individual correlations between the BCVA and SS-OCT parameters were analyzed. A stepwise multiple regression analysis was performed with the BCVA as a dependent variable and SS-OCT parameters as independent variables. After its creation, the accuracy of the prediction equation was verified in the verification group. Results: All the parameters, except for age and total corneal cylinder, showed statistically significant correlations with BCVA ( P < 0.0001). Using the stepwise multiple regression analysis, we selected 2 explanatory variables: root mean square of anterior corneal elevation (standardized regression coefficient: 1.221; P < 0.0001) and total comaAbstract : Purpose: This study aimed to predict the best-corrected visual acuity (BCVA) based on swept-source optical coherence tomography (SS-OCT) parameters in eyes with keratoconus. Methods: We retrospectively reviewed 135 eyes of 135 patients with keratoconus (mean age: 31.9 ± 12.4 years). The average keratometry value and BCVA (logarithm of the minimal angle of resolution [Snellen]) were 48.68 ± 5.44 diopter and 0.20 ± 0.36 (20/25), respectively. Eleven parameters were calculated using SS-OCT. Apart from the corneal height and elevation, all the other parameters were calculated from both anterior and posterior corneal OCT data. The patients were divided into 2 groups, 1 for creating the prediction equation (prediction group, 86 eyes) and another for verifying the equation (verification group, 49 eyes). In the former, individual correlations between the BCVA and SS-OCT parameters were analyzed. A stepwise multiple regression analysis was performed with the BCVA as a dependent variable and SS-OCT parameters as independent variables. After its creation, the accuracy of the prediction equation was verified in the verification group. Results: All the parameters, except for age and total corneal cylinder, showed statistically significant correlations with BCVA ( P < 0.0001). Using the stepwise multiple regression analysis, we selected 2 explanatory variables: root mean square of anterior corneal elevation (standardized regression coefficient: 1.221; P < 0.0001) and total coma aberration (standardized regression coefficient: −0.575; P = 0.001; adjusted R 2 = 0.546). The prediction was correct in 84.6% of the eyes within ±1 line of Snellen BCVA. Conclusions: Using the equation we derived from SS-OCT parameters is a promising method to predict visual function in patients with keratoconus. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Cornea. Volume 38:Issue 9(2019)
- Journal:
- Cornea
- Issue:
- Volume 38:Issue 9(2019)
- Issue Display:
- Volume 38, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2019-0038-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- keratoconus -- visual acuity -- prediction -- swept-source optical coherence tomography
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002043 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14205.xml