Schiotz Scleral Intraocular Pressure Readings Predict Goldmann Applanation Readings Better Than Rebound Tonometry. Issue 9 (September 2019)
- Record Type:
- Journal Article
- Title:
- Schiotz Scleral Intraocular Pressure Readings Predict Goldmann Applanation Readings Better Than Rebound Tonometry. Issue 9 (September 2019)
- Main Title:
- Schiotz Scleral Intraocular Pressure Readings Predict Goldmann Applanation Readings Better Than Rebound Tonometry
- Authors:
- Senthil, Sirisha
Chary, Raghava
Ali, Mohammed Hasnat
Choudhari, Nikhil
Badakere, Swathi
Krishnamurthy, Rashmi
Dikshit, Siddharth
Garudadri, Chandrasekhar - Abstract:
- Abstract : Purpose: To study the agreement between scleral intraocular pressure (IOP) measurements using the Schiotz, Icare, and Icare PRO tonometers versus Goldmann applanation tonometer (GAT) in eyes with nonscarred corneas. Methods: This cross-sectional study included 83 eyes of 55 subjects. The order of IOP estimation was the corneal GAT, followed by ICare, ICare PRO, and Schiotz on the corneal and temporal sclera. The agreement between different tonometers and the 95% limits of agreement (LoA) were assessed using Bland–Altman plots. The repeated measures correlation coefficient was calculated between GAT IOP and scleral Schiotz IOP, and the 95% confidence intervals were calculated by the bootstrap method. The linear mixed effects model was used (adjusted for both eyes of the subjects) to generate an equation to predict GAT IOP from scleral Schiotz IOP. The prediction model was validated with new data from 60 eyes. Statistical analyses were performed using "R" software (version 3.3.2). Results: Comparing the scleral IOP measurements, the mean IOP difference (95% LoA) was the lowest with Schiotz, underestimating by −1.21 mm Hg (7.32, −9.74). Both ICare and ICare PRO significantly overestimated GAT IOP: ICare, 24.6 mm Hg (53.2, −3.97); and ICare PRO, 21.56 mm Hg (52.9, −9.79). The correlation coefficient between scleral Schiotz and GAT IOP was 0.92 (95% bootstrap confidence interval: 0.89, 98). The derived predictive equation was . The mean difference between the predictedAbstract : Purpose: To study the agreement between scleral intraocular pressure (IOP) measurements using the Schiotz, Icare, and Icare PRO tonometers versus Goldmann applanation tonometer (GAT) in eyes with nonscarred corneas. Methods: This cross-sectional study included 83 eyes of 55 subjects. The order of IOP estimation was the corneal GAT, followed by ICare, ICare PRO, and Schiotz on the corneal and temporal sclera. The agreement between different tonometers and the 95% limits of agreement (LoA) were assessed using Bland–Altman plots. The repeated measures correlation coefficient was calculated between GAT IOP and scleral Schiotz IOP, and the 95% confidence intervals were calculated by the bootstrap method. The linear mixed effects model was used (adjusted for both eyes of the subjects) to generate an equation to predict GAT IOP from scleral Schiotz IOP. The prediction model was validated with new data from 60 eyes. Statistical analyses were performed using "R" software (version 3.3.2). Results: Comparing the scleral IOP measurements, the mean IOP difference (95% LoA) was the lowest with Schiotz, underestimating by −1.21 mm Hg (7.32, −9.74). Both ICare and ICare PRO significantly overestimated GAT IOP: ICare, 24.6 mm Hg (53.2, −3.97); and ICare PRO, 21.56 mm Hg (52.9, −9.79). The correlation coefficient between scleral Schiotz and GAT IOP was 0.92 (95% bootstrap confidence interval: 0.89, 98). The derived predictive equation was . The mean difference between the predicted GAT IOP and the actual GAT IOP was 0.96 mm Hg with narrow LoA (+1.79, −3.71), validating the prediction model. Conclusions: Among the tonometers tested, the scleral IOP measurements with Schiotz had the best agreement with the GAT although LoA were wide. The predictive equation may have great potential to predict GAT IOP from scleral IOP readings in eyes with scarred/prosthetic corneas. … (more)
- Is Part Of:
- Cornea. Volume 38:Issue 9(2019)
- Journal:
- Cornea
- Issue:
- Volume 38:Issue 9(2019)
- Issue Display:
- Volume 38, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2019-0038-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- Schiotz tonometer -- intraocular pressure -- scarred cornea -- keratoprosthesis -- tonometer -- ICare tonometer -- scleral IOP
Cornea -- Periodicals
Cornea -- Periodicals
Cornée -- Périodiques
617.719 - Journal URLs:
- http://journals.lww.com/corneajrnl/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICO.0000000000002033 ↗
- Languages:
- English
- ISSNs:
- 0277-3740
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3470.927500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14205.xml