An on-site dosimetry audit for high-energy electron beams. (January 2018)
- Record Type:
- Journal Article
- Title:
- An on-site dosimetry audit for high-energy electron beams. (January 2018)
- Main Title:
- An on-site dosimetry audit for high-energy electron beams
- Authors:
- de Prez, Leon
Heukelom, Stan
Jansen, Bartel
Jansen, Wim
van de Kamer, Jeroen
van Klink, Wenze
Kok, Elfried
Perik, Thijs
de Pooter, Jacco
Wittkämper, Frits - Abstract:
- Abstract: Background and purpose: External dosimetry audits are powerful quality assurance instruments for radiotherapy. The aim of this study was to implement an electron dosimetry audit based on a contemporary code of practice within the requirements for calibration laboratories performing proficiency tests. This involved the determination of suitable acceptance criteria based on thorough uncertainty analyses. Materials and methods: Subject of the audit was the determination of absorbed dose to water, D w, and the beam quality specifier, R 50, dos . Fifteen electron beams were measured in four institutes according to the Belgian-Dutch code of practice for high-energy electron beams. The expanded uncertainty ( k = 2) for the D w values was 3.6% for a Roos chamber calibrated in 60 Co and 3.2% for a Roos chamber cross-calibrated against a Farmer chamber. The expanded uncertainty for the beam quality specifier, R 50, dos, was 0.14 cm. The audit acceptance levels were based on the expanded uncertainties for the comparison results and estimated to be 2.4%. Results: The audit was implemented and validated successfully. All D w audit results were satisfactory with differences in D w values mostly smaller than 0.5% and always smaller than 1%. Except for one, differences in R 50, dos were smaller than 0.2 cm and always smaller than 0.3 cm. Conclusions: An electron dosimetry audit based on absorbed dose to water and present-day requirements for calibration laboratories performingAbstract: Background and purpose: External dosimetry audits are powerful quality assurance instruments for radiotherapy. The aim of this study was to implement an electron dosimetry audit based on a contemporary code of practice within the requirements for calibration laboratories performing proficiency tests. This involved the determination of suitable acceptance criteria based on thorough uncertainty analyses. Materials and methods: Subject of the audit was the determination of absorbed dose to water, D w, and the beam quality specifier, R 50, dos . Fifteen electron beams were measured in four institutes according to the Belgian-Dutch code of practice for high-energy electron beams. The expanded uncertainty ( k = 2) for the D w values was 3.6% for a Roos chamber calibrated in 60 Co and 3.2% for a Roos chamber cross-calibrated against a Farmer chamber. The expanded uncertainty for the beam quality specifier, R 50, dos, was 0.14 cm. The audit acceptance levels were based on the expanded uncertainties for the comparison results and estimated to be 2.4%. Results: The audit was implemented and validated successfully. All D w audit results were satisfactory with differences in D w values mostly smaller than 0.5% and always smaller than 1%. Except for one, differences in R 50, dos were smaller than 0.2 cm and always smaller than 0.3 cm. Conclusions: An electron dosimetry audit based on absorbed dose to water and present-day requirements for calibration laboratories performing proficiency tests was successfully implemented. It proved international traceability of the participants value with an uncertainty better than 3.6% ( k = 2). … (more)
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 5(2018)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 5(2018)
- Issue Display:
- Volume 5, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 5
- Issue:
- 2018
- Issue Sort Value:
- 2018-0005-2018-0000
- Page Start:
- 44
- Page End:
- 51
- Publication Date:
- 2018-01
- Subjects:
- Absorbed dose to water -- Audit -- Code of practice -- Dosimetry -- Electron beam -- Radiation therapy
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2018.02.001 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14199.xml