Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient‐reported outcomes. (17th October 2018)
- Record Type:
- Journal Article
- Title:
- Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient‐reported outcomes. (17th October 2018)
- Main Title:
- Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient‐reported outcomes
- Authors:
- Jung, Ronald E.
Al‐Nawas, Bilal
Araujo, Mauricio
Avila‐Ortiz, Gustavo
Barter, Stephen
Brodala, Nadine
Chappuis, Vivianne
Chen, Bo
De Souza, Andre
Almeida, Ricardo Faria
Fickl, Stefan
Finelle, Gary
Ganeles, Jeffrey
Gholami, Hadi
Hammerle, Christoph
Jensen, Simon
Jokstad, Asbjørn
Katsuyama, Hideaki
Kleinheinz, Johannes
Kunavisarut, Chatchai
Mardas, Nikos
Monje, Alberto
Papaspyridakos, Panos
Payer, Michael
Schiegnitz, Eik
Smeets, Ralf
Stefanini, Martina
ten Bruggenkate, Christiaan
Vazouras, Konstantinos
Weber, Hans‐Peter
Weingart, Dieter
Windisch, Péter
… (more) - Other Names:
- Wismeijer Daniel guestEditor.
Chen Stephen T. guestEditor. - Abstract:
- Abstract: Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐reported outcomes in implant dentistry. Focused questions on (a) short posterior dental implants (≤6 mm), (b) narrow diameter implants, (c) implant design (tapered compared to a non‐tapered implant design), and (d) medication‐related dental implant failures were addressed. Materials and methods: Four systematic reviews were prepared in advance of the Consensus Conference and were discussed among the participants of Group 1. Consensus statements, clinical recommendations, and recommendations for future research were based on structured group discussions until consensus was reached among the entire expert Group 1. The statements were then presented and accepted following further discussion and modifications as required by the plenary. Results: Short implants (≤6 mm) revealed a survival rate ranging from 86.7% to 100%, whereas standard implant survival rate ranged from 95% to 100% with a follow‐up from 1 to 5 years. Short implants demonstrated a higher variability and a higher Risk Ratio [RR: 1.24 (95% CI: 0.63, 2.44, p = 0.54)] for failure compared to standard implants. Narrow diameter implants (NDI) have been classified into three categories: Category 1: Implants with a diameter of <2.5 mm ("Mini‐implants"); Category 2: Implants with a diameter of 2.5 mm to <3.3 mm;Abstract: Objectives: The aim of Working Group 1 was to address the influence of different local (implant length, diameter, and design) and systemic (medications) factors on clinical, radiographic, and patient‐reported outcomes in implant dentistry. Focused questions on (a) short posterior dental implants (≤6 mm), (b) narrow diameter implants, (c) implant design (tapered compared to a non‐tapered implant design), and (d) medication‐related dental implant failures were addressed. Materials and methods: Four systematic reviews were prepared in advance of the Consensus Conference and were discussed among the participants of Group 1. Consensus statements, clinical recommendations, and recommendations for future research were based on structured group discussions until consensus was reached among the entire expert Group 1. The statements were then presented and accepted following further discussion and modifications as required by the plenary. Results: Short implants (≤6 mm) revealed a survival rate ranging from 86.7% to 100%, whereas standard implant survival rate ranged from 95% to 100% with a follow‐up from 1 to 5 years. Short implants demonstrated a higher variability and a higher Risk Ratio [RR: 1.24 (95% CI: 0.63, 2.44, p = 0.54)] for failure compared to standard implants. Narrow diameter implants (NDI) have been classified into three categories: Category 1: Implants with a diameter of <2.5 mm ("Mini‐implants"); Category 2: Implants with a diameter of 2.5 mm to <3.3 mm; Category 3: Implants with a diameter of 3.3 mm to 3.5 mm. Mean survival rates were 94.7 ± 5%, 97.3 ± 5% and 97.7 ± 2.3% for category 1, 2 and 3. Tapered versus non‐tapered implants demonstrated only insignificant differences regarding clinical, radiographic, and patient‐reported outcomes. The intake of certain selective serotonin reuptake inhibitors and proton pump inhibitors is associated with a statistically significant increased implant failure rate. The intake of bisphosphonates related to the treatment of osteoporosis was not associated with an increased implant failure rate. Conclusions: It is concluded that short implants (≤6 mm) are a valid option in situations of reduced bone height to avoid possible morbidity associated with augmentation procedures; however, they reveal a higher variability and lower predictability in survival rates. Narrow diameter implants with diameters of 2.5 mm and more demonstrated no difference in implant survival rates compared to standard diameter implants. In contrast, it is concluded that narrow diameter implants with diameters of less than 2.5 mm exhibited lower survival rates compared to standard diameter implants. It is further concluded that there are no differences between tapered versus non‐tapered dental implants. Certain medications such as selective serotonin reuptake inhibitors and proton pump inhibitors showed an association with a higher implant failure rate. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 29(2018)Supplement 16
- Journal:
- Clinical oral implants research
- Issue:
- Volume 29(2018)Supplement 16
- Issue Display:
- Volume 29, Issue 16 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 16
- Issue Sort Value:
- 2018-0029-0016-0000
- Page Start:
- 69
- Page End:
- 77
- Publication Date:
- 2018-10-17
- Subjects:
- biological complications -- clinical decision‐making -- dental implants -- drug -- endosseous implant -- epidemiology -- failure -- humans -- medication -- meta‐analysis -- narrow diameter -- osteotomy -- randomized controlled trials -- review -- short dental implants -- small dental implants -- survival
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.13342 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14197.xml