Efficacy of a strict surveillance policy towards inappropriateness of plasma transfusion. (August 2019)
- Record Type:
- Journal Article
- Title:
- Efficacy of a strict surveillance policy towards inappropriateness of plasma transfusion. (August 2019)
- Main Title:
- Efficacy of a strict surveillance policy towards inappropriateness of plasma transfusion
- Authors:
- Beverina, Ivo
Novelli, Chiara
Gatti, Arianna
Aloni, Alessandro
Grassi, Chiara
Latella, Stefania
Scalvini, Rita
Gatti, Cinzia
Brando, Bruno - Abstract:
- Abstract: Background: Plasma transfusion is not without risks. Despite a limited spectrum of indications, plasma is frequently used as prophylaxis in non-bleeding patients, to correct altered coagulation tests. A high rate of inappropriate use of plasma transfusion is frequently reported, as well as underdosage. Study design and methods: Since 2010 we started an education program that occurred in several phases to disseminate the knowledge of plasma transfusion guidelines. Since 2014 a 'zero tolerance' policy was applied: except for massive bleedings, plasma requests were prospectively evaluated, rejecting those without an appropriate indication. When indicated, at least 10 mL/Kg b.w.were issued. The previous five year period (2005–2009) served as control. Results: The number of patients transfused/year decreased by 67.6% vs the control period (149 vs 460), and the liters of plasma issued/year decreased by 70.4% (233 vs 795). The deepest fall was observed in acute care wards (-70.8%). The mean volume transfused per episode raised from 731 mL ± 70 to 879 mL ± 154. The Prothrombin Time ratio at the moment of transfusion request increased from a mean of 1.35 (Interquartile range 1.20–2.64) in the control period to 1.62 (Interquartile range 1.43–1.98) in the last period (p < 0.001). Conclusion: With a proactive educational approach a remarkable reduction of plasma order and administration has been obtained, without any consequence on morbidity and mortality and with an estimatedAbstract: Background: Plasma transfusion is not without risks. Despite a limited spectrum of indications, plasma is frequently used as prophylaxis in non-bleeding patients, to correct altered coagulation tests. A high rate of inappropriate use of plasma transfusion is frequently reported, as well as underdosage. Study design and methods: Since 2010 we started an education program that occurred in several phases to disseminate the knowledge of plasma transfusion guidelines. Since 2014 a 'zero tolerance' policy was applied: except for massive bleedings, plasma requests were prospectively evaluated, rejecting those without an appropriate indication. When indicated, at least 10 mL/Kg b.w.were issued. The previous five year period (2005–2009) served as control. Results: The number of patients transfused/year decreased by 67.6% vs the control period (149 vs 460), and the liters of plasma issued/year decreased by 70.4% (233 vs 795). The deepest fall was observed in acute care wards (-70.8%). The mean volume transfused per episode raised from 731 mL ± 70 to 879 mL ± 154. The Prothrombin Time ratio at the moment of transfusion request increased from a mean of 1.35 (Interquartile range 1.20–2.64) in the control period to 1.62 (Interquartile range 1.43–1.98) in the last period (p < 0.001). Conclusion: With a proactive educational approach a remarkable reduction of plasma order and administration has been obtained, without any consequence on morbidity and mortality and with an estimated saving since 2014 of 750, 000 €. A 'zero tolerance' policy can be effectively implemented only with a thorough workup with the local physicians, including repeated rounds of information and refreshing of the updated transfusion practice and knowledge of the established guidelines over the time. … (more)
- Is Part Of:
- Transfusion and apheresis science. Volume 58:Number 4(2019)
- Journal:
- Transfusion and apheresis science
- Issue:
- Volume 58:Number 4(2019)
- Issue Display:
- Volume 58, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 58
- Issue:
- 4
- Issue Sort Value:
- 2019-0058-0004-0000
- Page Start:
- 423
- Page End:
- 428
- Publication Date:
- 2019-08
- Subjects:
- Patient blood management -- Plasma transfusion -- Appropriateness
Blood -- Transfusion -- Periodicals
Hemapheresis -- Periodicals
615.39 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14730502 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/14730502 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/14730502 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.transci.2019.03.022 ↗
- Languages:
- English
- ISSNs:
- 1473-0502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14195.xml