Reliability of CT‐based texture features: Phantom study. Issue 8 (20th June 2019)
- Record Type:
- Journal Article
- Title:
- Reliability of CT‐based texture features: Phantom study. Issue 8 (20th June 2019)
- Main Title:
- Reliability of CT‐based texture features: Phantom study
- Authors:
- Varghese, Bino A.
Hwang, Darryl
Cen, Steven Y.
Levy, Joshua
Liu, Derek
Lau, Christopher
Rivas, Marielena
Desai, Bhushan
Goodenough, David J.
Duddalwar, Vinay A. - Abstract:
- Abstract: Objective: To determine the intra‐, inter‐ and test‐retest variability of CT‐based texture analysis (CTTA) metrics. Materials and methods: In this study, we conducted a series of CT imaging experiments using a texture phantom to evaluate the performance of a CTTA panel on routine abdominal imaging protocols. The phantom comprises of three different regions with various textures found in tumors. The phantom was scanned on two CT scanners viz. the Philips Brilliance 64 CT and Toshiba Aquilion Prime 160 CT scanners. The intra‐scanner variability of the CTTA metrics was evaluated across imaging parameters such as slice thickness, field of view, post‐reconstruction filtering, tube voltage, and tube current. For each scanner and scanning parameter combination, we evaluated the performance of eight different types of texture quantification techniques on a predetermined region of interest (ROI) within the phantom image using 235 different texture metrics. We conducted the repeatability (test‐retest) and robustness (intra‐scanner) test on both the scanners and the reproducibility test was conducted by comparing the inter‐scanner differences in the repeatability and robustness to identify reliable CTTA metrics. Reliable metrics are those metrics that are repeatable, reproducible and robust. Results: As expected, the robustness, repeatability and reproducibility of CTTA metrics are variably sensitive to various scanner and scanning parameters. Entropy of Fast FourierAbstract: Objective: To determine the intra‐, inter‐ and test‐retest variability of CT‐based texture analysis (CTTA) metrics. Materials and methods: In this study, we conducted a series of CT imaging experiments using a texture phantom to evaluate the performance of a CTTA panel on routine abdominal imaging protocols. The phantom comprises of three different regions with various textures found in tumors. The phantom was scanned on two CT scanners viz. the Philips Brilliance 64 CT and Toshiba Aquilion Prime 160 CT scanners. The intra‐scanner variability of the CTTA metrics was evaluated across imaging parameters such as slice thickness, field of view, post‐reconstruction filtering, tube voltage, and tube current. For each scanner and scanning parameter combination, we evaluated the performance of eight different types of texture quantification techniques on a predetermined region of interest (ROI) within the phantom image using 235 different texture metrics. We conducted the repeatability (test‐retest) and robustness (intra‐scanner) test on both the scanners and the reproducibility test was conducted by comparing the inter‐scanner differences in the repeatability and robustness to identify reliable CTTA metrics. Reliable metrics are those metrics that are repeatable, reproducible and robust. Results: As expected, the robustness, repeatability and reproducibility of CTTA metrics are variably sensitive to various scanner and scanning parameters. Entropy of Fast Fourier Transform‐based texture metrics was overall most reliable across the two scanners and scanning conditions. Post‐processing techniques that reduce image noise while preserving the underlying edges associated with true anatomy or pathology bring about significant differences in radiomic reliability compared to when they were not used. Conclusion: Following large‐scale validation, identification of reliable CTTA metrics can aid in conducting large‐scale multicenter CTTA analysis using sample sets acquired using different imaging protocols, scanners etc. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 8(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 8(2019)
- Issue Display:
- Volume 20, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 8
- Issue Sort Value:
- 2019-0020-0008-0000
- Page Start:
- 155
- Page End:
- 163
- Publication Date:
- 2019-06-20
- Subjects:
- computed tomography -- imaging -- phantom study -- reliability -- texture analysis
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12666 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14194.xml