Diagnostic Accuracy of Point of Care Tests for Diagnosing Celiac Disease: A Systematic Review and Meta-Analysis. Issue 7 (August 2019)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy of Point of Care Tests for Diagnosing Celiac Disease: A Systematic Review and Meta-Analysis. Issue 7 (August 2019)
- Main Title:
- Diagnostic Accuracy of Point of Care Tests for Diagnosing Celiac Disease
- Authors:
- Singh, Prashant
Arora, Ananya
Strand, Tor A.
Leffler, Daniel A.
Mäki, Markku
Kelly, Ciaran P.
Ahuja, Vineet
Makharia, Govind K. - Abstract:
- Abstract : Goals: To perform a systematic review and meta-analysis to estimate the overall diagnostic accuracy of point of care tests (POCTs) for diagnosing celiac disease (CD). Background: Recently, POCTs for CD have been developed and are commercially available. Studies have reported significant variability in their sensitivity (70% to 100%) and specificity (85% to 100%). Study: We searched MEDLINE, EMBASE databases, and the Cochrane library through June 2017. Positive reference test was defined as villous atrophy along with positive celiac-specific serology and/or clinical improvement after gluten-free diet. Normal duodenal biopsy was defined as negative reference test. Bivariate random-effect model was used to present the summary estimates of sensitivities and specificities along with 95% confidence regions We assessed methodologic quality using the quality assessment of diagnostic accuracy studies-2 tool. Results: The pooled sensitivity and specificity of all POCTs (based on tTG or DGP or tTG+Anti-gliadin antibodies) for diagnosing CD were 94.0% [95% confidence interval (CI), 89.9-96.5] and 94.4% (95% CI, 90.9-96.5), respectively. The pooled positive and negative likelihood ratios for POCTs were 16.7 and 0.06, respectively. The pooled sensitivity and specificity for IgA-tTG-based POCTs were 90.5% (95% CI, 82.3-95.1) and 94.8% (95% CI, 92.5-96.4), respectively. Conclusions: The pooled sensitivity and specificity of POCTs in diagnosing CD are high. POCTs may be used toAbstract : Goals: To perform a systematic review and meta-analysis to estimate the overall diagnostic accuracy of point of care tests (POCTs) for diagnosing celiac disease (CD). Background: Recently, POCTs for CD have been developed and are commercially available. Studies have reported significant variability in their sensitivity (70% to 100%) and specificity (85% to 100%). Study: We searched MEDLINE, EMBASE databases, and the Cochrane library through June 2017. Positive reference test was defined as villous atrophy along with positive celiac-specific serology and/or clinical improvement after gluten-free diet. Normal duodenal biopsy was defined as negative reference test. Bivariate random-effect model was used to present the summary estimates of sensitivities and specificities along with 95% confidence regions We assessed methodologic quality using the quality assessment of diagnostic accuracy studies-2 tool. Results: The pooled sensitivity and specificity of all POCTs (based on tTG or DGP or tTG+Anti-gliadin antibodies) for diagnosing CD were 94.0% [95% confidence interval (CI), 89.9-96.5] and 94.4% (95% CI, 90.9-96.5), respectively. The pooled positive and negative likelihood ratios for POCTs were 16.7 and 0.06, respectively. The pooled sensitivity and specificity for IgA-tTG-based POCTs were 90.5% (95% CI, 82.3-95.1) and 94.8% (95% CI, 92.5-96.4), respectively. Conclusions: The pooled sensitivity and specificity of POCTs in diagnosing CD are high. POCTs may be used to screen for CD, especially in areas with limited access to laboratory-based testing. Further research assessing the diagnostic accuracy of individual POCTs and comparing it with other available POCTs is needed. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of clinical gastroenterology. Volume 53:Issue 7(2019)
- Journal:
- Journal of clinical gastroenterology
- Issue:
- Volume 53:Issue 7(2019)
- Issue Display:
- Volume 53, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 53
- Issue:
- 7
- Issue Sort Value:
- 2019-0053-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- serology -- anti-tissue transglutaminase antibody -- endomysial antibody -- prevalence
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Digestive organs -- Diseases
Gastroenterology
Periodicals
Periodicals
616.33005 - Journal URLs:
- http://journals.lww.com/jcge/Pages/default.aspx ↗
http://www.jcge.com ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00004836-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MCG.0000000000001081 ↗
- Languages:
- English
- ISSNs:
- 0192-0790
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.470000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14189.xml