Comparison of single photon emission CT (SPECT) with SPECT/CT imaging in preoperative localization of parathyroid adenomas: A cost‐effectiveness analysis. (5th February 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of single photon emission CT (SPECT) with SPECT/CT imaging in preoperative localization of parathyroid adenomas: A cost‐effectiveness analysis. (5th February 2016)
- Main Title:
- Comparison of single photon emission CT (SPECT) with SPECT/CT imaging in preoperative localization of parathyroid adenomas: A cost‐effectiveness analysis
- Authors:
- Barber, Brittany
Moher, Conrad
Côté, David
Fung, Elaine
O'Connell, Daniel
Dziegielewski, Peter
Harris, Jeffrey - Abstract:
- Abstract: Background: Controversy exists regarding the superiority of single photon emission CT (SPECT)/CT over SPECT for preoperative localization of parathyroid adenomas in primary hyperparathyroidism (PHPT), as well as the cost‐effectiveness. Methods: A retrospective review was undertaken of patients undergoing surgery for PHPT from January 2009 to August 2014. Ultrasound and SPECT (ultrasound‐SPECT) or SPECT/CT (ultrasound‐SPECT/CT) were performed for each patient. Sensitivity and positive predictive value (PPV) of each modality were calculated. Cost‐effectiveness was determined by an incremental cost‐effectiveness ratio (ICER) analysis. Results: Two hundred fifty‐nine patients with 266 parathyroid adenomas were included in the study. Lateralization sensitivity and PPV of ultrasound‐SPECT were 85.1% and 98.2%, respectively. The lateralization sensitivity and PPV of ultrasound‐SPECT/CT were 86.9% and 99.4%, respectively. A cost of $2499.22 (CAD) per additional parathyroid adenoma detection by ultrasound‐SPECT/CT was determined from the ICER analysis. Conclusion: Similar sensitivities and PPVs were observed between ultrasound‐SPECT and ultrasound‐SPECT/CT in preoperatively lateralizing parathyroid adenomas, with relatively equivalent cost‐effectiveness. © 2016 Wiley Periodicals, Inc. Head Neck 38 : E2062–E2065, 2016
- Is Part Of:
- Head & neck. Volume 38(2016)Supplement 1
- Journal:
- Head & neck
- Issue:
- Volume 38(2016)Supplement 1
- Issue Display:
- Volume 38, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2016-0038-0001-0000
- Page Start:
- E2062
- Page End:
- E2065
- Publication Date:
- 2016-02-05
- Subjects:
- parathyroid -- adenoma -- single photon emission CT (SPECT/CT) -- sestamibi -- localization
Head -- Diseases -- Periodicals
Neck -- Diseases -- Periodicals
Head -- Periodicals
Neck -- Periodicals
Face -- Periodicals
617.51059 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0347 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/hed.24379 ↗
- Languages:
- English
- ISSNs:
- 1043-3074
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4274.608500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14186.xml