Accelerated 3D T2w‐imaging of the prostate with 1‐millimeter isotropic resolution in less than 3 minutes. Issue 2 (21st April 2019)
- Record Type:
- Journal Article
- Title:
- Accelerated 3D T2w‐imaging of the prostate with 1‐millimeter isotropic resolution in less than 3 minutes. Issue 2 (21st April 2019)
- Main Title:
- Accelerated 3D T2w‐imaging of the prostate with 1‐millimeter isotropic resolution in less than 3 minutes
- Authors:
- Vidya Shankar, Rohini
Roccia, Elisa
Cruz, Gastao
Neji, Radhouene
Botnar, René
Prezzi, Davide
Goh, Vicky
Prieto, Claudia
Dregely, Isabel - Abstract:
- Abstract : Purpose: To achieve 3D T2 w imaging of the prostate with 1‐mm isotropic resolution in less than 3 min. Methods: We devised and implemented a 3D T2 ‐prepared multishot balanced steady state free precession (T2 prep‐bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV‐SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board‐approved study. Image quality metrics (subjective signal‐to‐noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed‐rank and Kruskal‐Wallis non‐parametric tests to prostate images acquired using a fully sampled 3D T2 prep‐bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2 w acquisitions. A P ‐value < 0.05 was considered significant. Results: The 3× accelerated 3D T2 prep‐bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2 prep‐bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2 prep‐bSSFP, fully sampled T2 prep‐bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different (Abstract : Purpose: To achieve 3D T2 w imaging of the prostate with 1‐mm isotropic resolution in less than 3 min. Methods: We devised and implemented a 3D T2 ‐prepared multishot balanced steady state free precession (T2 prep‐bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV‐SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board‐approved study. Image quality metrics (subjective signal‐to‐noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed‐rank and Kruskal‐Wallis non‐parametric tests to prostate images acquired using a fully sampled 3D T2 prep‐bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2 w acquisitions. A P ‐value < 0.05 was considered significant. Results: The 3× accelerated 3D T2 prep‐bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2 prep‐bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2 prep‐bSSFP, fully sampled T2 prep‐bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different ( P > 0.05). Conclusion: 3D T2 w images of the prostate with 1‐mm isotropic resolution can be acquired in less than 3 min, with image quality that is comparable to a clinical standard 3D TSE sequence but only takes a third of the acquisition time. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 2(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 2(2019)
- Issue Display:
- Volume 82, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 2
- Issue Sort Value:
- 2019-0082-0002-0000
- Page Start:
- 721
- Page End:
- 731
- Publication Date:
- 2019-04-21
- Subjects:
- 3D prostate imaging -- fast imaging -- isotropic resolution -- T2‐weighted MRI -- TV‐SENSE
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27764 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14185.xml