An 8‐channel receive array for improved 31P MRSI of the whole brain at 3T. Issue 2 (21st March 2019)
- Record Type:
- Journal Article
- Title:
- An 8‐channel receive array for improved 31P MRSI of the whole brain at 3T. Issue 2 (21st March 2019)
- Main Title:
- An 8‐channel receive array for improved 31P MRSI of the whole brain at 3T
- Authors:
- van Uden, Mark J.
Peeters, Tom H.
Rijpma, Anne
Rodgers, Christopher T.
Heerschap, Arend
Scheenen, Tom W. J. - Abstract:
- Abstract : Purpose: To demonstrate a 1 H/ 31 P whole human brain volume coil configuration for 3 Tesla with separate 31 P transmit and receive components that maintains 1 H MRS performance and delivers optimal 31 P MRSI with 1 H decoupling. Methods: We developed an 8‐channel 31 P receive array coil covering the head to be used as an insert for a commercial double‐tuned 1 H/ 31 P birdcage transmit‐receive coil. This retains the possibility of using low‐power rectangular pulses for 1 H‐decoupled 3D 31 P MRSI (nominal resolution 17.6 cm 3 ; acquisition duration 13 min) but increases the SNR with the receive sensitivity of 31 P surface coils. The performance of the combined coil setup was evaluated by measuring 1 H and 31 P SNR with and without the 31 P receive array and by assessing the effect of the receive array on the transmit efficiencies of the birdcage coil. Results: Compared to the birdcage coil alone, the 31 P insert in combination with the birdcage achieved an average 31 P SNR gain of 1.4 ± 0.4 in a center partition of the brain. The insert did not cause losses in 1 H MRS performance and transmit efficiency, whereas for 31 P approximately 20% more power was needed to achieve the same γB1. Conclusion: The new coil configuration allows 1 H MRSI and optimal 1 H‐decoupled 3D 31 P MRSI, with increased SNR of the human brain without patient repositioning, for clinical and research purposes at 3 Tesla.
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 2(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 2(2019)
- Issue Display:
- Volume 82, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 2
- Issue Sort Value:
- 2019-0082-0002-0000
- Page Start:
- 825
- Page End:
- 832
- Publication Date:
- 2019-03-21
- Subjects:
- 1H‐decoupling -- 3 Tesla -- 31P MR spectroscopic imaging -- brain -- RF array coil
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27736 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14185.xml