IUVS echelle‐mode observations of interplanetary hydrogen: Standard for calibration and reference for cavity variations between Earth and Mars during MAVEN cruise. Issue 2 (2nd February 2017)
- Record Type:
- Journal Article
- Title:
- IUVS echelle‐mode observations of interplanetary hydrogen: Standard for calibration and reference for cavity variations between Earth and Mars during MAVEN cruise. Issue 2 (2nd February 2017)
- Main Title:
- IUVS echelle‐mode observations of interplanetary hydrogen: Standard for calibration and reference for cavity variations between Earth and Mars during MAVEN cruise
- Authors:
- Mayyasi, Majd
Clarke, John
Quémerais, Eric
Katushkina, Olga
Bhattacharyya, Dolon
Chaufray, Jean‐Yves
Bertaux, Jean‐Loup
McClintock, Bill
Stewart, Ian
Holsclaw, Greg
Deighan, Justin
Chaffin, Michael
Schneider, Nick
Jakosky, Bruce - Abstract:
- Abstract: The high‐resolution echelle mode of the Imaging Ultraviolet Spectrograph (IUVS) instrument on the Mars Atmosphere and Volatile Evolution mission has been designed to measure D and H Lyman α emissions from the Martian atmosphere to obtain key information about the physical processes by which water escapes into space. Toward this goal, the absolute calibration of the instrument is critical for determining the D and H densities, the D/H ratio, and the escape flux of water. The instrument made observations of interplanetary hydrogen (IPH) along multiple look directions and conducted several postlaunch calibration campaigns during cruise as well as during orbit around Mars. The calibration efforts monitored instrument degradation and produced a consistent calibration factor at the hydrogen Lyman α wavelength (121.567 nm). The instrument was calibrated with the diffuse emission of interplanetary hydrogen (IPH) as a standard candle using measurements and model results from the Solar Wind Anisotropies (SWAN) instrument. Validation of the calibrated instrument was made by (1) comparisons to simultaneous observations of the IPH made with the lower resolution FUV mode of the IUVS instrument that were independently calibrated by using standard stars and by (2) comparisons to same‐day observations of Mars at hydrogen Lyman α made with the Hubble Space Telescope that were calculated with a radiative transfer model. Adopted FUV mode values and Hubble Space Telescope‐based modelAbstract: The high‐resolution echelle mode of the Imaging Ultraviolet Spectrograph (IUVS) instrument on the Mars Atmosphere and Volatile Evolution mission has been designed to measure D and H Lyman α emissions from the Martian atmosphere to obtain key information about the physical processes by which water escapes into space. Toward this goal, the absolute calibration of the instrument is critical for determining the D and H densities, the D/H ratio, and the escape flux of water. The instrument made observations of interplanetary hydrogen (IPH) along multiple look directions and conducted several postlaunch calibration campaigns during cruise as well as during orbit around Mars. The calibration efforts monitored instrument degradation and produced a consistent calibration factor at the hydrogen Lyman α wavelength (121.567 nm). The instrument was calibrated with the diffuse emission of interplanetary hydrogen (IPH) as a standard candle using measurements and model results from the Solar Wind Anisotropies (SWAN) instrument. Validation of the calibrated instrument was made by (1) comparisons to simultaneous observations of the IPH made with the lower resolution FUV mode of the IUVS instrument that were independently calibrated by using standard stars and by (2) comparisons to same‐day observations of Mars at hydrogen Lyman α made with the Hubble Space Telescope that were calculated with a radiative transfer model. Adopted FUV mode values and Hubble Space Telescope‐based model results agreed with the echelle SWAN calibrated values to within 6% and 4%, respectively. The calibrated IUVS instrument can be used to interpret emissions of atmospheric species at Mars for insights into water evolution at the planet, as well as observed IPH measurements made during cruise for further insights into dynamics of the inner heliosphere. Key Points: IPH diffuse emission is used to calibrate the MAVEN IUVS instrument Stable calibration factor is obtained to facilitate interpretation of observations Spectral characteristics of IPH observed by the MAVEN echelle instrument are consistent with previous observations … (more)
- Is Part Of:
- Journal of geophysical research. Volume 122:Issue 2(2017)
- Journal:
- Journal of geophysical research
- Issue:
- Volume 122:Issue 2(2017)
- Issue Display:
- Volume 122, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 122
- Issue:
- 2
- Issue Sort Value:
- 2017-0122-0002-0000
- Page Start:
- 2089
- Page End:
- 2105
- Publication Date:
- 2017-02-02
- Subjects:
- echelle -- UV -- Mars -- spectrograph -- IPH -- calibration
Magnetospheric physics -- Periodicals
Space environment -- Periodicals
Cosmic physics -- Periodicals
Planets -- Atmospheres -- Periodicals
Heliosphere (Astrophysics) -- Periodicals
Geophysics -- Periodicals
523.01 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2169-9402 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/2016JA023466 ↗
- Languages:
- English
- ISSNs:
- 2169-9380
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4995.010000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14184.xml