Residual chemical oxygen demand (COD) fractionation in bio-treated coking wastewater integrating solution property characterization. (15th September 2019)
- Record Type:
- Journal Article
- Title:
- Residual chemical oxygen demand (COD) fractionation in bio-treated coking wastewater integrating solution property characterization. (15th September 2019)
- Main Title:
- Residual chemical oxygen demand (COD) fractionation in bio-treated coking wastewater integrating solution property characterization
- Authors:
- Wei, Cong
Wu, Hengping
Kong, Qiaoping
Wei, Jingyue
Feng, Chunhua
Qiu, Guanglei
Wei, Chaohai
Li, Fusheng - Abstract:
- Abstract: The refractory nature of residual COD in bio-treated coking wastewater (BTCW) creates barriers for its further treatment and reclamation. It is necessary to fractionate the residual COD in BTCW associated with characterization of solution properties. In this paper, a stepwise process composed of membrane filtration, coagulation, adsorption and ozonation was proposed to fractionate residual COD in the BTCW, in which the COD was stepwise reduced to near zero. In addition, the correlation between COD and water quality indexes as well as solution properties were discussed together with a safety assessment of the water quality. Results showed that the residual COD fractionation percentage contributed by suspended solids, colloids, dissolved organics and reductive inorganic substances in the BTCW was 43.7%, 22.1%, 26.2% and 4.9%, respectively. By stepwise fractionating of these substances, the residual COD was reduced from 168.8 to 5.2 mg L −1, and the UV254 value decreased from 1.90 to 0.15 cm −1 . In addition, the particle size of the dominant substances contributing to the residual COD was smaller than 450 nm. Among these substances, the hydrophobic fraction accounted for 78.66% (in the term of TOC). Three-dimensional excitation-emission matrix (3D-EEM) analysis showed that hydrophobic neutral substances (HON) were the main fluorescence constituent in the BTCW, which was highly removable by adsorption. The residual COD after adsorption was mainly composed of reductiveAbstract: The refractory nature of residual COD in bio-treated coking wastewater (BTCW) creates barriers for its further treatment and reclamation. It is necessary to fractionate the residual COD in BTCW associated with characterization of solution properties. In this paper, a stepwise process composed of membrane filtration, coagulation, adsorption and ozonation was proposed to fractionate residual COD in the BTCW, in which the COD was stepwise reduced to near zero. In addition, the correlation between COD and water quality indexes as well as solution properties were discussed together with a safety assessment of the water quality. Results showed that the residual COD fractionation percentage contributed by suspended solids, colloids, dissolved organics and reductive inorganic substances in the BTCW was 43.7%, 22.1%, 26.2% and 4.9%, respectively. By stepwise fractionating of these substances, the residual COD was reduced from 168.8 to 5.2 mg L −1, and the UV254 value decreased from 1.90 to 0.15 cm −1 . In addition, the particle size of the dominant substances contributing to the residual COD was smaller than 450 nm. Among these substances, the hydrophobic fraction accounted for 78.66% (in the term of TOC). Three-dimensional excitation-emission matrix (3D-EEM) analysis showed that hydrophobic neutral substances (HON) were the main fluorescence constituent in the BTCW, which was highly removable by adsorption. The residual COD after adsorption was mainly composed of reductive inorganic substances. Apart from pursuit of high COD removal rates, more emphasis should be given to the removal of toxic COD. Correlations were observed between the residual COD and water quality indicators as well as solution properties, providing a guideline for optimized removal of residual COD in the BTCW. In summary, these results gave a referential information about the nature of residual COD in the BTCW for the selection of advanced treatment technologies and the management of water quality safety. Graphical abstract: Image 1 Highlights: The residual COD in bio-treated coking wastewater was fractionated. A stepwise process was proposed to fractionate the residual COD. Solution properties of the residual COD were characterized. COD toward zero was not equal to water safety through water quality assessment. … (more)
- Is Part Of:
- Journal of environmental management. Volume 246(2019)
- Journal:
- Journal of environmental management
- Issue:
- Volume 246(2019)
- Issue Display:
- Volume 246, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 246
- Issue:
- 2019
- Issue Sort Value:
- 2019-0246-2019-0000
- Page Start:
- 324
- Page End:
- 333
- Publication Date:
- 2019-09-15
- Subjects:
- Chemical oxygen demand (COD) -- Bio-treated coking wastewater -- Solution properties -- Correlation analysis -- Water quality assessment
Environmental policy -- Periodicals
Environmental management -- Periodicals
Environment -- Periodicals
Ecology -- Periodicals
363.705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03014797 ↗
http://www.elsevier.com/journals ↗
http://www.idealibrary.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.jenvman.2019.06.001 ↗
- Languages:
- English
- ISSNs:
- 0301-4797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4979.383000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14160.xml