Cherenkov radiation‐based three‐dimensional position‐sensitive PET detector: A Monte Carlo study. Issue 5 (23rd March 2018)
- Record Type:
- Journal Article
- Title:
- Cherenkov radiation‐based three‐dimensional position‐sensitive PET detector: A Monte Carlo study. Issue 5 (23rd March 2018)
- Main Title:
- Cherenkov radiation‐based three‐dimensional position‐sensitive PET detector: A Monte Carlo study
- Authors:
- Ota, Ryosuke
Yamada, Ryoko
Moriya, Takahiro
Hasegawa, Tomoyuki - Abstract:
- Abstract : Purpose: Cherenkov radiation has recently received attention due to its prompt emission phenomenon, which has the potential to improve the timing performance of radiation detectors dedicated to positron emission tomography (PET). In this study, a Cherenkov‐based three‐dimensional (3D) position‐sensitive radiation detector was proposed, which is composed of a monolithic lead fluoride (PbF2 ) crystal and a photodetector array of which the signals can be readout independently. Methods: Monte Carlo simulations were performed to estimate the performance of the proposed detector. The position‐ and time resolution were evaluated under various practical conditions. The radiator size and various properties of the photodetector, e.g., readout pitch and single photon timing resolution (SPTR), were parameterized. The single photon time response of the photodetector was assumed to be a single Gaussian for the simplification. The photo detection efficiency of the photodetector was ideally 100% for all wavelengths. Compton scattering was included in simulations, but partly analyzed. To estimate the position at which a γ ‐ray interacted in the Cherenkov radiator, the center‐of‐gravity (COG) method was employed. In addition, to estimate the depth‐of‐interaction (DOI) principal component analysis (PCA), which is a multivariate analysis method and has been used to identify the patterns in data, was employed. The time–space distribution of Cherenkov photons was quantified to performAbstract : Purpose: Cherenkov radiation has recently received attention due to its prompt emission phenomenon, which has the potential to improve the timing performance of radiation detectors dedicated to positron emission tomography (PET). In this study, a Cherenkov‐based three‐dimensional (3D) position‐sensitive radiation detector was proposed, which is composed of a monolithic lead fluoride (PbF2 ) crystal and a photodetector array of which the signals can be readout independently. Methods: Monte Carlo simulations were performed to estimate the performance of the proposed detector. The position‐ and time resolution were evaluated under various practical conditions. The radiator size and various properties of the photodetector, e.g., readout pitch and single photon timing resolution (SPTR), were parameterized. The single photon time response of the photodetector was assumed to be a single Gaussian for the simplification. The photo detection efficiency of the photodetector was ideally 100% for all wavelengths. Compton scattering was included in simulations, but partly analyzed. To estimate the position at which a γ ‐ray interacted in the Cherenkov radiator, the center‐of‐gravity (COG) method was employed. In addition, to estimate the depth‐of‐interaction (DOI) principal component analysis (PCA), which is a multivariate analysis method and has been used to identify the patterns in data, was employed. The time–space distribution of Cherenkov photons was quantified to perform PCA. To evaluate coincidence time resolution (CTR), the time difference of two independent γ ‐ray events was calculated. The detection time was defined as the first photon time after the SPTR of the photodetector was taken into account. Results: The position resolution on the photodetector plane could be estimated with high accuracy, by using a small number of Cherenkov photons. Moreover, PCA showed an ability to estimate the DOI. The position resolution heavily depends on the pitch of the photodetector array and the radiator thickness. If the readout pitch were ideally 0 and practically 3 mm, a full‐width at half‐maximum (FWHM) of 0.348 and 1.92 mm was achievable with a 10‐mm‐thick PbF2 crystal, respectively. Furthermore, first‐order correlation could be observed between the primary principal component and the true DOI. To obtain a coincidence timing resolution better than 100‐ps FWHM with a 20‐mm‐thick PbF2 crystal, a photodetector with SPTR of better than σ = 30 ps was necessary. Conclusions: From these results, the improvement of SPTR allows us to achieve CTR better than 100‐ps FWHM, even in the case where a 20‐mm‐thick radiator is used. Our proposed detector has the potential to estimate the 3D interaction position of γ ‐rays in the radiator, using only time and space information of Cherenkov photons. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 5(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 5(2018)
- Issue Display:
- Volume 45, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2018-0045-0005-0000
- Page Start:
- 1999
- Page End:
- 2008
- Publication Date:
- 2018-03-23
- Subjects:
- Cherenkov radiation (Cerenkov) -- lead fluoride (PbF2) -- principal component analysis
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12851 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14170.xml