A 32‐channel combined RF and B0 shim array for 3T brain imaging. Issue 1 (17th February 2015)
- Record Type:
- Journal Article
- Title:
- A 32‐channel combined RF and B0 shim array for 3T brain imaging. Issue 1 (17th February 2015)
- Main Title:
- A 32‐channel combined RF and B0 shim array for 3T brain imaging
- Authors:
- Stockmann, Jason P.
Witzel, Thomas
Keil, Boris
Polimeni, Jonathan R.
Mareyam, Azma
LaPierre, Cristen
Setsompop, Kawin
Wald, Lawrence L. - Abstract:
- Abstract : Purpose: We add user‐controllable direct currents (DC) to the individual elements of a 32‐channel radio‐frequency (RF) receive array to provide B0 shimming ability while preserving the array's reception sensitivity and parallel imaging performance. Methods: Shim performance using constrained DC current (±2.5A) is simulated for brain arrays ranging from 8 to 128 elements. A 32‐channel 3‐tesla brain array is realized using inductive chokes to bridge the tuning capacitors on each RF loop. The RF and B0 shimming performance is assessed in bench and imaging measurements. Results: The addition of DC currents to the 32‐channel RF array is achieved with minimal disruption of the RF performance and/or negative side effects such as conductor heating or mechanical torques. The shimming results agree well with simulations and show performance superior to third‐order spherical harmonic (SH) shimming. Imaging tests show the ability to reduce the standard frontal lobe susceptibility‐induced fields and improve echo planar imaging geometric distortion. The simulation of 64‐ and 128‐channel brain arrays suggest that even further shimming improvement is possible (equivalent to up to 6th‐order SH shim coils). Conclusion: Including user‐controlled shim currents on the loops of a conventional highly parallel brain array coil is feasible with modest current levels and produces improved B0 shimming performance over standard second‐order SH shimming. Magn Reson Med 75:441–451, 2016. ©Abstract : Purpose: We add user‐controllable direct currents (DC) to the individual elements of a 32‐channel radio‐frequency (RF) receive array to provide B0 shimming ability while preserving the array's reception sensitivity and parallel imaging performance. Methods: Shim performance using constrained DC current (±2.5A) is simulated for brain arrays ranging from 8 to 128 elements. A 32‐channel 3‐tesla brain array is realized using inductive chokes to bridge the tuning capacitors on each RF loop. The RF and B0 shimming performance is assessed in bench and imaging measurements. Results: The addition of DC currents to the 32‐channel RF array is achieved with minimal disruption of the RF performance and/or negative side effects such as conductor heating or mechanical torques. The shimming results agree well with simulations and show performance superior to third‐order spherical harmonic (SH) shimming. Imaging tests show the ability to reduce the standard frontal lobe susceptibility‐induced fields and improve echo planar imaging geometric distortion. The simulation of 64‐ and 128‐channel brain arrays suggest that even further shimming improvement is possible (equivalent to up to 6th‐order SH shim coils). Conclusion: Including user‐controlled shim currents on the loops of a conventional highly parallel brain array coil is feasible with modest current levels and produces improved B0 shimming performance over standard second‐order SH shimming. Magn Reson Med 75:441–451, 2016. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 1(2016:Jan.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 1(2016:Jan.)
- Issue Display:
- Volume 75, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 1
- Issue Sort Value:
- 2016-0075-0001-0000
- Page Start:
- 441
- Page End:
- 451
- Publication Date:
- 2015-02-17
- Subjects:
- multi‐coil shimming -- RF receive arrays -- echo planar imaging -- geometric distortion -- brain MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25587 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14170.xml