Validation of GPU‐accelerated superposition–convolution dose computations for the Small Animal Radiation Research Platform. Issue 5 (15th April 2018)
- Record Type:
- Journal Article
- Title:
- Validation of GPU‐accelerated superposition–convolution dose computations for the Small Animal Radiation Research Platform. Issue 5 (15th April 2018)
- Main Title:
- Validation of GPU‐accelerated superposition–convolution dose computations for the Small Animal Radiation Research Platform
- Authors:
- Cho, Nathan
Tsiamas, Panagiotis
Velarde, Esteban
Tryggestad, Erik
Jacques, Robert
Berbeco, Ross
McNutt, Todd
Kazanzides, Peter
Wong, John - Abstract:
- Abstract : Purpose: The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on‐board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)‐accelerated Superposition–Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS) for SARRP. This paper describes the validation of the SC method for the kilovoltage energy by comparing with EBT2 film measurements and Monte Carlo (MC) simulations. Methods: MC data were simulated by EGSnrc code with 3 × 10 8 –1.5 × 10 9 histories, while 21 photon energy bins were used to model the 220 kVp x‐rays in the SC method. Various types of phantoms including plastic water, cork, graphite, and aluminum were used to encompass the range of densities of mouse organs. For the comparison, percentage depth dose (PDD) of SC, MC, and film measurements were analyzed. Cross beam (x, y) dosimetric profiles of SC and film measurements are also presented. Correction factors (CFz) to convert SC to MC dose‐to‐medium are derived from the SC and MC simulations in homogeneous phantoms of aluminum and graphite to improve the estimation. Results: The SC method produces dose values that are within 5% of film measurements and MC simulations in the flat regions of the profile. The dose is less accurate at the edges, due to factors such as geometric uncertainties of film placement and difference in dose calculation grids. Conclusion: The GPU‐acceleratedAbstract : Purpose: The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on‐board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)‐accelerated Superposition–Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS) for SARRP. This paper describes the validation of the SC method for the kilovoltage energy by comparing with EBT2 film measurements and Monte Carlo (MC) simulations. Methods: MC data were simulated by EGSnrc code with 3 × 10 8 –1.5 × 10 9 histories, while 21 photon energy bins were used to model the 220 kVp x‐rays in the SC method. Various types of phantoms including plastic water, cork, graphite, and aluminum were used to encompass the range of densities of mouse organs. For the comparison, percentage depth dose (PDD) of SC, MC, and film measurements were analyzed. Cross beam (x, y) dosimetric profiles of SC and film measurements are also presented. Correction factors (CFz) to convert SC to MC dose‐to‐medium are derived from the SC and MC simulations in homogeneous phantoms of aluminum and graphite to improve the estimation. Results: The SC method produces dose values that are within 5% of film measurements and MC simulations in the flat regions of the profile. The dose is less accurate at the edges, due to factors such as geometric uncertainties of film placement and difference in dose calculation grids. Conclusion: The GPU‐accelerated Superposition–Convolution dose computation method was successfully validated with EBT2 film measurements and MC calculations. The SC method offers much faster computation speed than MC and provides calculations of both dose‐to‐water in medium and dose‐to‐medium in medium. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 5(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 5(2018)
- Issue Display:
- Volume 45, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2018-0045-0005-0000
- Page Start:
- 2252
- Page End:
- 2265
- Publication Date:
- 2018-04-15
- Subjects:
- dosimetric validation -- small animal radiotherapy -- superposition‐convolution
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12862 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14169.xml