Procedural safety and long‐term follow‐up after pacemaker implantation in nonagenarians. Issue 10 (22nd October 2018)
- Record Type:
- Journal Article
- Title:
- Procedural safety and long‐term follow‐up after pacemaker implantation in nonagenarians. Issue 10 (22nd October 2018)
- Main Title:
- Procedural safety and long‐term follow‐up after pacemaker implantation in nonagenarians
- Authors:
- Dang, Duc
Galand, Vincent
Loirat, Aurélie
Auffret, Vincent
Behar, Nathalie
Mabo, Philippe
Daubert, Jean‐Claude
Leclercq, Christophe
Martins, Raphaël P. - Abstract:
- Abstract : Background: The rate of pacemaker (PM) implantations is constantly growing. Since life expectancy of the population is projected to increase, a large number of nonagenarian patients will need PM implantation. We aimed at analyzing short‐ and long‐term outcomes after PM implantation in nonagenarians. Methods: Patients aged ≥90 years referred for PM implantation from 2004 to 2017 were included. The primary clinical endpoint was total mortality. Secondary endpoints included procedure‐related and in‐hospital complications. Results: A total of 172 patients were included (92.6 ± 2.1 years, from 90.0 to 101.4 years). Procedure duration was 50.0 ± 19.7 minutes. Most of the patients had VVI devices implanted (143 pts, 83.1%) and mean hospital stay was 3.5 ± 1.5 days. Nine patients (5.2%) had short‐term device‐related complications and 29 patients (16.8%) had post‐procedural complications, non‐related to the implantation, including four leading to patients' death. During a follow‐up of 22.5 months (interquartile range: 7.3‐38.0), 94 patients (54.7%) died. Survival rates were 82.9% (95% confidence interval [CI]: 76.0‐88.0), 73.7% (95% CI: 65.7‐80.1) and 37.5% (95% CI: 27.5‐47.5) after 1, 2, and 5 years, respectively. The Charlson comorbidity index was a predictive factor of procedural complications (odds ratio = 1.33; 95% CI: 1.05‐1.69, P = 0.02) while having a complication (hazard ratio [HR] = 4.04; 95% CI: 1.79‐9.11, P = 0.001) and atrial fibrillation (HR = 1.63; 95% CI:Abstract : Background: The rate of pacemaker (PM) implantations is constantly growing. Since life expectancy of the population is projected to increase, a large number of nonagenarian patients will need PM implantation. We aimed at analyzing short‐ and long‐term outcomes after PM implantation in nonagenarians. Methods: Patients aged ≥90 years referred for PM implantation from 2004 to 2017 were included. The primary clinical endpoint was total mortality. Secondary endpoints included procedure‐related and in‐hospital complications. Results: A total of 172 patients were included (92.6 ± 2.1 years, from 90.0 to 101.4 years). Procedure duration was 50.0 ± 19.7 minutes. Most of the patients had VVI devices implanted (143 pts, 83.1%) and mean hospital stay was 3.5 ± 1.5 days. Nine patients (5.2%) had short‐term device‐related complications and 29 patients (16.8%) had post‐procedural complications, non‐related to the implantation, including four leading to patients' death. During a follow‐up of 22.5 months (interquartile range: 7.3‐38.0), 94 patients (54.7%) died. Survival rates were 82.9% (95% confidence interval [CI]: 76.0‐88.0), 73.7% (95% CI: 65.7‐80.1) and 37.5% (95% CI: 27.5‐47.5) after 1, 2, and 5 years, respectively. The Charlson comorbidity index was a predictive factor of procedural complications (odds ratio = 1.33; 95% CI: 1.05‐1.69, P = 0.02) while having a complication (hazard ratio [HR] = 4.04; 95% CI: 1.79‐9.11, P = 0.001) and atrial fibrillation (HR = 1.63; 95% CI: [1.02‐2.63], P = 0.043) were predictors of post‐implantation death. Conclusion: PM implantation in nonagenarians is safe, with a low risk of procedural complications, but many comorbidities‐related complications can occur. Caution should be taken in this old and frail population since complications significantly impact patients' survival. … (more)
- Is Part Of:
- Clinical cardiology. Volume 41:Issue 10(2018)
- Journal:
- Clinical cardiology
- Issue:
- Volume 41:Issue 10(2018)
- Issue Display:
- Volume 41, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 10
- Issue Sort Value:
- 2018-0041-0010-0000
- Page Start:
- 1315
- Page End:
- 1321
- Publication Date:
- 2018-10-22
- Subjects:
- complications -- nonagenarian -- pacemaker
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.23083 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14175.xml