Improved segmental myocardial strain reproducibility using deformable registration algorithms compared with feature tracking cardiac MRI and speckle tracking echocardiography. Issue 2 (28th December 2017)
- Record Type:
- Journal Article
- Title:
- Improved segmental myocardial strain reproducibility using deformable registration algorithms compared with feature tracking cardiac MRI and speckle tracking echocardiography. Issue 2 (28th December 2017)
- Main Title:
- Improved segmental myocardial strain reproducibility using deformable registration algorithms compared with feature tracking cardiac MRI and speckle tracking echocardiography
- Authors:
- Wang, Jie
Li, Weihao
Sun, Jiayu
Liu, Hong
Kang, Yu
Yang, Dan
Yu, Liuyu
Greiser, Andreas
Zhou, Xiaoyue
Han, Yuchi
Chen, Yucheng - Abstract:
- Abstract : Background: Segmental myocardial strain using feature tracking (FT) cardiac MRI is not acceptable due to poor reproducibility. Purpose: To assess the reproducibility of left ventricle (LV) segmental myocardial strain measured by deformation registration algorithm (DRA). Study Type: Prospective clinical trial. Subjects: Sixteen healthy volunteers and 28 hypertrophic cardiomyopathy (HCM) patients. Field Strength/Sequence: Retrospective ECG gating cardiac MRI imaging was performed at 3.0T with a steady‐state free precession (SSFP) sequence. Assessment: LV global and segmental myocardial strains were analyzed by DRA, FT, and speckle tracking echocardiography (STE) by two experienced observers and the reproducibility of global and segmental strains were compared. Statistical Tests: Reproducibility was tested by coefficient of variation (COV) and intraclass correlation coefficient (ICC). Receiver operator curves as well as comparison of areas under the curve (AUC) were analyzed. Results: DRA showed the best observer agreement on segmental strain evaluated by ICC, LS (longitudinal strain): intraobserver variability range (0.98, 1.00), interobserver variability range (0.83, 0.92), CS (circumferential strain): intraobserver variability range (0.90, 0.99), interobserver variability range (0.80, 0.97), RS (radial strain): intraobserver variability range (0.84, 0.99), interobserver variability range (0.85, 0.99). Segmental LS, CS, and RS agreements evaluated by COV for FT andAbstract : Background: Segmental myocardial strain using feature tracking (FT) cardiac MRI is not acceptable due to poor reproducibility. Purpose: To assess the reproducibility of left ventricle (LV) segmental myocardial strain measured by deformation registration algorithm (DRA). Study Type: Prospective clinical trial. Subjects: Sixteen healthy volunteers and 28 hypertrophic cardiomyopathy (HCM) patients. Field Strength/Sequence: Retrospective ECG gating cardiac MRI imaging was performed at 3.0T with a steady‐state free precession (SSFP) sequence. Assessment: LV global and segmental myocardial strains were analyzed by DRA, FT, and speckle tracking echocardiography (STE) by two experienced observers and the reproducibility of global and segmental strains were compared. Statistical Tests: Reproducibility was tested by coefficient of variation (COV) and intraclass correlation coefficient (ICC). Receiver operator curves as well as comparison of areas under the curve (AUC) were analyzed. Results: DRA showed the best observer agreement on segmental strain evaluated by ICC, LS (longitudinal strain): intraobserver variability range (0.98, 1.00), interobserver variability range (0.83, 0.92), CS (circumferential strain): intraobserver variability range (0.90, 0.99), interobserver variability range (0.80, 0.97), RS (radial strain): intraobserver variability range (0.84, 0.99), interobserver variability range (0.85, 0.99). Segmental LS, CS, and RS agreements evaluated by COV for FT and STE were poor. LV global myocardial strain of HCM was significantly lower than controls for all applied techniques, but global CS by DRA had better accuracy compared to FT or STE for distinguishing HCM from healthy subjects: AUC 0.880 (DRA) vs. 0.577 (FT) or 0.736 (STE), P < 0.05. Data Conclusions: DRA is a reliable and robust analysis tool for segmental myocardial strain. Global CS by DRA allows discrimination between HCM and normal controls with better accuracy compared with FT and STE. Level of Evidence : 1 Technical Efficacy : Stage 2 J. MAGN. RESON. IMAGING 2018;48:404–414. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 48:Issue 2(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 48:Issue 2(2018)
- Issue Display:
- Volume 48, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 48
- Issue:
- 2
- Issue Sort Value:
- 2018-0048-0002-0000
- Page Start:
- 404
- Page End:
- 414
- Publication Date:
- 2017-12-28
- Subjects:
- deformable registration algorithms -- feature‐tracking -- speckle‐tracking echocardiography -- hypertrophic cardiomyopathy
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25937 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14173.xml