Model predictive filtering MR thermometry: Effects of model inaccuracies, k‐space reduction factor, and temperature increase rate. Issue 1 (25th February 2015)
- Record Type:
- Journal Article
- Title:
- Model predictive filtering MR thermometry: Effects of model inaccuracies, k‐space reduction factor, and temperature increase rate. Issue 1 (25th February 2015)
- Main Title:
- Model predictive filtering MR thermometry: Effects of model inaccuracies, k‐space reduction factor, and temperature increase rate
- Authors:
- Odéen, Henrik
Todd, Nick
Dillon, Christopher
Payne, Allison
Parker, Dennis L. - Abstract:
- Abstract : Purpose: Evaluate effects of model parameter inaccuracies (thermal conductivity, k, and ultrasound power deposition density, Q ), k‐space reduction factor ( R ), and rate of temperature increase ( T ˙ ) in a thermal model‐based reconstruction for MR‐thermometry during focused‐ultrasound heating. Methods: Simulations and ex vivo experiments were performed to investigate the accuracy of the thermal model and the model predictive filtering (MPF) algorithm for varying R and T ˙, and their sensitivity to errors in k and Q . Ex vivo data was acquired with a segmented EPI pulse sequence to achieve large field‐of‐view (192 × 162 × 96 mm) four‐dimensional temperature maps with high spatiotemporal resolution (1.5 × 1.5 × 2.0 mm, 1.7 s). Results: In the simulations, 50% errors in k and Q resulted in maximum temperature root mean square errors (RMSE) of 6°C for model only and 3°C for MPF. Using recently developed methods, estimates of k and Q were accurate to within 3%. The RMSE between MPF and true temperature increased with R and T ˙ . In the ex vivo study the RMSE remained below 0.7°C for R ranging from 4 to 12 and T ˙ of 0.28–0.75°C/s. Conclusion: Errors in MPF temperatures occur due to errors in k and Q . These MPF temperature errors increase with increase in R and T ˙, but are smaller than those obtained using the thermal model alone. Magn Reson Med 75:207–216, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 1(2016:Jan.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 1(2016:Jan.)
- Issue Display:
- Volume 75, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 1
- Issue Sort Value:
- 2016-0075-0001-0000
- Page Start:
- 207
- Page End:
- 216
- Publication Date:
- 2015-02-25
- Subjects:
- MR thermometry -- PRF -- HIFU -- MPF -- MRTI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25622 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14170.xml