Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline. (November 2020)
- Record Type:
- Journal Article
- Title:
- Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline. (November 2020)
- Main Title:
- Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline
- Authors:
- Galindo, Rodolfo J.
Umpierrez, Guillermo E.
Rushakoff, Robert J.
Basu, Ananda
Lohnes, Suzanne
Nichols, James H.
Spanakis, Elias K.
Espinoza, Juan
Palermo, Nadine E.
Awadjie, Dessa Garnett
Bak, Leigh
Buckingham, Bruce
Cook, Curtiss B.
Freckmann, Guido
Heinemann, Lutz
Hovorka, Roman
Mathioudakis, Nestoras
Newman, Tonya
O'Neal, David N.
Rickert, Michaela
Sacks, David B.
Seley, Jane Jeffrie
Wallia, Amisha
Shang, Trisha
Zhang, Jennifer Y.
Han, Julia
Klonoff, David C. - Abstract:
- This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed onThis article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 14:Number 6(2020:Nov.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 14:Number 6(2020:Nov.)
- Issue Display:
- Volume 14, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 14
- Issue:
- 6
- Issue Sort Value:
- 2020-0014-0006-0000
- Page Start:
- 1035
- Page End:
- 1064
- Publication Date:
- 2020-11
- Subjects:
- automated insulin dosing -- continuous glucose monitor -- COVID-19 -- guideline -- hospital
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296820954163 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14144.xml