A rotation method to calibrate BPM electric offsets. (November 2019)
- Record Type:
- Journal Article
- Title:
- A rotation method to calibrate BPM electric offsets. (November 2019)
- Main Title:
- A rotation method to calibrate BPM electric offsets
- Authors:
- Wang, M.W.
Wang, D.
Wang, Z.M.
Qiu, M.T.
Zheng, S.X.
Ma, P.F.
Guan, X.L.
Huang, W.H.
Wang, X.W. - Abstract:
- Abstract: Beam position monitor is a key instrument for machine commissioning. To measure beam position accurately, offline calibrations to acquire the sensitivity and offsets of the BPM are essential prerequisites. A new method to calibrate the BPM electric offset is proposed in this paper. By measuring the location variation of the BPM electric center after rotating the BPM 180 degrees, the BPM offset can be derived. The method is more convenient, universal and accurate than the traditional methods. The method is successfully applied to calibrate the button BPM of Xi'an Proton Application Facility. The repetitive measurement error is 20.8 μm.
- Is Part Of:
- Journal of physics. Volume 1350(2019)
- Journal:
- Journal of physics
- Issue:
- Volume 1350(2019)
- Issue Display:
- Volume 1350, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 1350
- Issue:
- 1
- Issue Sort Value:
- 2019-1350-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11
- Subjects:
- Physics -- Congresses
530.5 - Journal URLs:
- http://www.iop.org/EJ/journal/1742-6596 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1742-6596/1350/1/012154 ↗
- Languages:
- English
- ISSNs:
- 1742-6588
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5036.223000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14112.xml