Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy. Issue 4 (October 2020)
- Record Type:
- Journal Article
- Title:
- Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy. Issue 4 (October 2020)
- Main Title:
- Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy
- Authors:
- De Bernardo, Maddalena
Cornetta, Palmiro
Marotta, Giuseppe
Salerno, Giulio
De Pascale, Ilaria
Rosa, Nicola - Abstract:
- Objective: To compare corneal thickness (CT) measurements using the CEM-530 (Nidal, Gamagori, Japan) and Pentacam HR (Oculus, Wetzlar, Germany). Methods: The CT of 209 healthy subjects (209 right eyes) aged 24 to 89 years (71.35 ± 10.72 years) was measured at the corneal apex (CA), pupil center (PC), and thinnest point (TP) with the Pentacam HR and at the corneal center with the CEM-530 in random order at the same time of day. Results: A good correlation but statistically significant difference was found between the CEM-530 and Pentacam HR measurements at the CA (6.10 ± 8.12 µm, R 2 = 0.8947), PC (7.46 ± 8.57 µm, R 2 = 0.8826), and TP (12.44 ± 10.04 µm, R 2 = 0.8392). Comparison of the two devices produced the following regression formulas: y = 0.8859x + 57.644 for the CA, y = 0.8852x +56.657 for the PC, and y = 0.8557x + 68.148 for the TP, where x is the CT obtained with the CEM-530 and y is that obtained with the Pentacam HR. Conclusions: These findings indicate that the CEM-530 produces a thicker corneal measurement than the Pentacam HR. The herein-proposed correcting factors are needed to reliably compare these devices.
- Is Part Of:
- Journal of international medical research. Volume 48:Issue 4(2020)
- Journal:
- Journal of international medical research
- Issue:
- Volume 48:Issue 4(2020)
- Issue Display:
- Volume 48, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 48
- Issue:
- 4
- Issue Sort Value:
- 2020-0048-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Cornea -- corneal thickness -- Pentacam HR -- CEM-530 -- specular microscopy -- regression formula
Medicine -- Periodicals
Pharmacology -- Periodicals
610.5 - Journal URLs:
- http://imr.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0300060519892385 ↗
- Languages:
- English
- ISSNs:
- 0300-0605
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14090.xml