Direct shear failure in concrete joints exposed to elevated temperatures. (October 2020)
- Record Type:
- Journal Article
- Title:
- Direct shear failure in concrete joints exposed to elevated temperatures. (October 2020)
- Main Title:
- Direct shear failure in concrete joints exposed to elevated temperatures
- Authors:
- Ahmad, Subhan
Bhargava, Pradeep
Chourasia, Ajay - Abstract:
- Abstract: Push off type specimens were tested to study the impact of different elevated temperatures on the shear capacity of concrete. Specimens fabricated with concrete of 40 MPa were exposed to heating in an electric furnace up to 350, 550, and 750 °C. Heated samples were cooled naturally up to the room temperature. Results of the unheated and heated specimens revealed that exposure temperatures of 350, 550, and 750 °C reduced the shear capacity of concrete by 18.85, 29.6, and 52.74%, respectively. A simplified method was also suggested for the computation of the shear capacity of concrete after elevated temperatures. The proposed method provided precise estimates of the shear capacity of concrete exposed to high temperatures.
- Is Part Of:
- Structures. Volume 27(2020)
- Journal:
- Structures
- Issue:
- Volume 27(2020)
- Issue Display:
- Volume 27, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 2020
- Issue Sort Value:
- 2020-0027-2020-0000
- Page Start:
- 1851
- Page End:
- 1859
- Publication Date:
- 2020-10
- Subjects:
- Shear capacity -- Direct shear -- Elevated temperature -- Analysis -- Prediction
Structural engineering -- Periodicals
624.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520124 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.istruc.2020.07.074 ↗
- Languages:
- English
- ISSNs:
- 2352-0124
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14035.xml