Methacrylic acid copolymer coating of polypropylene mesh chamber improves subcutaneous islet engraftment. (November 2020)
- Record Type:
- Journal Article
- Title:
- Methacrylic acid copolymer coating of polypropylene mesh chamber improves subcutaneous islet engraftment. (November 2020)
- Main Title:
- Methacrylic acid copolymer coating of polypropylene mesh chamber improves subcutaneous islet engraftment
- Authors:
- Coindre, Virginie F.
Kinney, Sean M.
Sefton, Michael V. - Abstract:
- Abstract: Subcutaneous devices can be used to house therapeutic cells such as pancreatic islets so that the cells can be retrieved. However, a high number of cells may be required to reverse diabetes, since a portion of the graft can be lost after transplantation due to ischemia and therefore the right device design is important. Increasing the vascularity of the subcutaneous space prior to cell transplantation is a strategic goal for cell transplantation, as it promotes islet survival, glucose-sensing and insulin secretion. In this study, a porous cell transplantation device was coated with 40% methacrylic acid-co-isodecyl acrylate (MAA-co-IDA), a biomaterial which promotes a vascular response without additional biologics. Three weeks after device implantation, the vessel density surrounding the device was double that of an uncoated device. The vasculature was mature and connected to the host bloodstream, as demonstrated by perfusion studies and histology. The tissue response to coated devices demonstrated lower levels of inflammation, measured by reduced gene expression of i-NOS and IL1β, and increased expression of IL4 . Syngeneic islets (300 islet equivalents) transplanted into the prevascularized coated device were able to return diabetic animals to normoglycemia for up to 11 weeks and resolve a glucose bolus similarly to non-diabetic mice by 3 weeks post-transplantation. We expect that the vessels and microenvironment resulting from the device coating are permissive toAbstract: Subcutaneous devices can be used to house therapeutic cells such as pancreatic islets so that the cells can be retrieved. However, a high number of cells may be required to reverse diabetes, since a portion of the graft can be lost after transplantation due to ischemia and therefore the right device design is important. Increasing the vascularity of the subcutaneous space prior to cell transplantation is a strategic goal for cell transplantation, as it promotes islet survival, glucose-sensing and insulin secretion. In this study, a porous cell transplantation device was coated with 40% methacrylic acid-co-isodecyl acrylate (MAA-co-IDA), a biomaterial which promotes a vascular response without additional biologics. Three weeks after device implantation, the vessel density surrounding the device was double that of an uncoated device. The vasculature was mature and connected to the host bloodstream, as demonstrated by perfusion studies and histology. The tissue response to coated devices demonstrated lower levels of inflammation, measured by reduced gene expression of i-NOS and IL1β, and increased expression of IL4 . Syngeneic islets (300 islet equivalents) transplanted into the prevascularized coated device were able to return diabetic animals to normoglycemia for up to 11 weeks and resolve a glucose bolus similarly to non-diabetic mice by 3 weeks post-transplantation. We expect that the vessels and microenvironment resulting from the device coating are permissive to islet survival and thus enabled islets to reverse diabetes. … (more)
- Is Part Of:
- Biomaterials. Volume 259(2020)
- Journal:
- Biomaterials
- Issue:
- Volume 259(2020)
- Issue Display:
- Volume 259, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 259
- Issue:
- 2020
- Issue Sort Value:
- 2020-0259-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- Methacrylic acid copolymer -- Coating -- Vascularization -- Cell delivery -- Islet transplantation
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2020.120324 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14021.xml