Efficacy and safety of the ab interno gelatin stent in severe pseudoexfoliation glaucoma compared to non-pseudoexfoliation glaucoma at 6 months. Issue 5 (September 2020)
- Record Type:
- Journal Article
- Title:
- Efficacy and safety of the ab interno gelatin stent in severe pseudoexfoliation glaucoma compared to non-pseudoexfoliation glaucoma at 6 months. Issue 5 (September 2020)
- Main Title:
- Efficacy and safety of the ab interno gelatin stent in severe pseudoexfoliation glaucoma compared to non-pseudoexfoliation glaucoma at 6 months
- Authors:
- Dar, Nimrod
Sharon, Tal
Hecht, Idan
Kalev-Landoy, Maya
Burgansky-Eliash, Zvia - Abstract:
- Purpose: To compare the efficacy and safety of the XEN45 Gel Stent surgery between patients with and without severe pseudoexfoliation glaucoma. Methods: In this retrospective, single-center, comparative chart review, records of 24 eyes of 23 patients with pseudoexfoliation glaucoma and 24 eyes of 23 patients with non-pseudoexfoliation glaucoma with severe glaucoma, defined as uncontrolled intraocular pressure on maximally tolerated medical therapy, were reviewed. All patients were treated with XEN45 Gel Stent surgery, in either a standalone procedure (84.8%) or combined with phacoemulsification (15.2%). Mean intraocular pressure, mean number of intraocular pressure-lowering medications, change in best-corrected visual acuity and needling or rescue surgery rates were assessed. Success was defined as at least 20% decrease in baseline intraocular pressure among treatment-free patients. Results: Patient characteristics were similar between the groups. At 6 months, intraocular pressure in the pseudoexfoliation glaucoma group decreased by 32% (24.3 ± 9 mmHg–14.8 ± 7 mmHg, p < 0.001), with comparable decrease in intraocular pressure in the non-pseudoexfoliation glaucoma group (22.6 ± 7 mmHg–16.7 ± 6 mmHg, p = 0.011). Similar rates of patients required topical anti-glaucoma therapy (29% vs 22%, p = 0.559), needling (54% vs 37%, p = 0.247), and rescue trabeculectomy (13% in both, p = 1.00) at the last follow-up. However, intraocular pressure decreased more in the pseudoexfoliationPurpose: To compare the efficacy and safety of the XEN45 Gel Stent surgery between patients with and without severe pseudoexfoliation glaucoma. Methods: In this retrospective, single-center, comparative chart review, records of 24 eyes of 23 patients with pseudoexfoliation glaucoma and 24 eyes of 23 patients with non-pseudoexfoliation glaucoma with severe glaucoma, defined as uncontrolled intraocular pressure on maximally tolerated medical therapy, were reviewed. All patients were treated with XEN45 Gel Stent surgery, in either a standalone procedure (84.8%) or combined with phacoemulsification (15.2%). Mean intraocular pressure, mean number of intraocular pressure-lowering medications, change in best-corrected visual acuity and needling or rescue surgery rates were assessed. Success was defined as at least 20% decrease in baseline intraocular pressure among treatment-free patients. Results: Patient characteristics were similar between the groups. At 6 months, intraocular pressure in the pseudoexfoliation glaucoma group decreased by 32% (24.3 ± 9 mmHg–14.8 ± 7 mmHg, p < 0.001), with comparable decrease in intraocular pressure in the non-pseudoexfoliation glaucoma group (22.6 ± 7 mmHg–16.7 ± 6 mmHg, p = 0.011). Similar rates of patients required topical anti-glaucoma therapy (29% vs 22%, p = 0.559), needling (54% vs 37%, p = 0.247), and rescue trabeculectomy (13% in both, p = 1.00) at the last follow-up. However, intraocular pressure decreased more in the pseudoexfoliation glaucoma group among treatment-free patients (–10.1 ± 8.0 mmHg vs −4.1 ± 8.1 mmHg, p = 0.043), and final intraocular pressure was lower in the pseudoexfoliation glaucoma group (12.2 ± 3.5 mmHg vs 15.8 ± 5.7 mmHg, p = 0.044). Conclusions: The XEN45 Gel Stent implant demonstrated similar efficacy and safety among severe pseudoexfoliation glaucoma and non-pseudoexfoliation glaucoma patients. Greater magnitude of decreased intraocular pressure occurred among treatment-free pseudoexfoliation glaucoma patients. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 30:Issue 5(2020)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 30:Issue 5(2020)
- Issue Display:
- Volume 30, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2020-0030-0005-0000
- Page Start:
- 1028
- Page End:
- 1033
- Publication Date:
- 2020-09
- Subjects:
- Pseudoexfoliation glaucoma -- XEN 45 gel stent -- trabeculectomy -- intra-ocular pressure
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/1120672119848277 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14020.xml