Critical shaft height for complete smoke exhaustion during fire at the worst longitudinal fire location in tunnels with natural ventilation. (September 2020)
- Record Type:
- Journal Article
- Title:
- Critical shaft height for complete smoke exhaustion during fire at the worst longitudinal fire location in tunnels with natural ventilation. (September 2020)
- Main Title:
- Critical shaft height for complete smoke exhaustion during fire at the worst longitudinal fire location in tunnels with natural ventilation
- Authors:
- Zhao, Peng
Chen, Tao
Yuan, Zhongyuan
Xie, Yuanyi
Yu, Nanyang - Abstract:
- Abstract: In this study, the smoke control for fire situations in tunnels with naturally ventilated shafts was studied based on a 1/20 reduced-scale tunnel model, and the effects of the longitudinal fire location, shaft settings, and heat release rate (HRR) on the smoke control were discussed. The experimental results show that a worst longitudinal fire location for smoke control exists. Moreover, the critical shaft height for complete smoke exhaustion was studied experimentally and theoretically. According to the experimental results, the critical shaft height is almost independent of the HRR. With increasing shaft length, the critical shaft height decreases first and then remains stable until it finally decreases to zero. Furthermore, it increases with increasing interval between two shafts. In addition, a theoretical model for predicting the critical shaft height was developed and validated. The research results can serve as a useful reference for the design of natural ventilation systems with vertical shafts for the control of tunnel fires. Highlights: A worst longitudinal fire location for smoke control exists. Critical shaft height is independent of the heat release rate. Critical shaft height decreases and then stays stable with increasing shaft length. A theoretical model for critical shaft height was developed and validated.
- Is Part Of:
- Fire safety journal. Volume 116(2020)
- Journal:
- Fire safety journal
- Issue:
- Volume 116(2020)
- Issue Display:
- Volume 116, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 116
- Issue:
- 2020
- Issue Sort Value:
- 2020-0116-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Tunnel fire -- Natural ventilation -- Worst longitudinal fire location for smoke control -- Critical shaft height -- Complete smoke exhaustion
Fire prevention -- Periodicals
Incendies -- Prévention -- Recherche -- Périodiques
Fire prevention -- Research
Periodicals
628.92205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03797112 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.firesaf.2020.103207 ↗
- Languages:
- English
- ISSNs:
- 0379-7112
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3933.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14019.xml