Detecting early erosive tooth wear using an intraoral scanner system. (September 2020)
- Record Type:
- Journal Article
- Title:
- Detecting early erosive tooth wear using an intraoral scanner system. (September 2020)
- Main Title:
- Detecting early erosive tooth wear using an intraoral scanner system
- Authors:
- Michou, Stavroula
Vannahme, Christoph
Ekstrand, Kim R.
Benetti, Ana R. - Abstract:
- Abstract: Objectives: To assess the feasibility of detecting and monitoring early erosive tooth wear using a 3D intraoral scanner (IOS) aided by specific software. Methods: Extracted sound permanent teeth were assembled in two shortened artificial dental arches and scanned at different intervals with an IOS (3Shape TRIOS® 3) before and after an erosion/abrasion protocol ( i.e. 1 h up to 24 h immersion in citric acid solution and subsequent brushing). The 3D models obtained at consecutive time points were superimposed with the baseline model using dedicated software (3Shape TRIOS® Patient Monitoring, version 2.1.1.0) and reference surface alignment. Surface profile differences between the baseline 3D model and the respective models from different time points were expressed as tooth substance loss. Non-parametric tests were used to assess the significance of tooth substance loss at different time points. Spearman's correlation was applied between the tooth substance loss at the end of each erosion/abrasion cycle and the immersion time in acid. Results: Significant tooth substance loss (0.08 mm, IQR = 0.05) was detected by the software after 3 h of erosive-abrasive challenge (p = 0.045). The overall median loss increased gradually from baseline to 24 h showing a strong correlation with the immersion time in acid ( rs = 0.971, p < 0.01). Conclusions: The use of an IOS aided by specific software showed good performance for early detection and monitoring of tooth wear in vitroAbstract: Objectives: To assess the feasibility of detecting and monitoring early erosive tooth wear using a 3D intraoral scanner (IOS) aided by specific software. Methods: Extracted sound permanent teeth were assembled in two shortened artificial dental arches and scanned at different intervals with an IOS (3Shape TRIOS® 3) before and after an erosion/abrasion protocol ( i.e. 1 h up to 24 h immersion in citric acid solution and subsequent brushing). The 3D models obtained at consecutive time points were superimposed with the baseline model using dedicated software (3Shape TRIOS® Patient Monitoring, version 2.1.1.0) and reference surface alignment. Surface profile differences between the baseline 3D model and the respective models from different time points were expressed as tooth substance loss. Non-parametric tests were used to assess the significance of tooth substance loss at different time points. Spearman's correlation was applied between the tooth substance loss at the end of each erosion/abrasion cycle and the immersion time in acid. Results: Significant tooth substance loss (0.08 mm, IQR = 0.05) was detected by the software after 3 h of erosive-abrasive challenge (p = 0.045). The overall median loss increased gradually from baseline to 24 h showing a strong correlation with the immersion time in acid ( rs = 0.971, p < 0.01). Conclusions: The use of an IOS aided by specific software showed good performance for early detection and monitoring of tooth wear in vitro and has promising potential for in vivo application. Clinical significance: Detection and monitoring of early erosive tooth wear can be reliably aided by intraoral scanning supported by specific software. The measurement error and uncertainty involved in this method should be taken into consideration when interpreting the tooth substance loss measurements. Furthermore, presuming the difficulty in defining reference surfaces in vivo, clinical validation is needed to determine the system's in vivo performance. … (more)
- Is Part Of:
- Journal of dentistry. Volume 100(2020:Sep.)
- Journal:
- Journal of dentistry
- Issue:
- Volume 100(2020:Sep.)
- Issue Display:
- Volume 100 (2020)
- Year:
- 2020
- Volume:
- 100
- Issue Sort Value:
- 2020-0100-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Tooth wear -- Tooth erosion -- Imaging -- Three-dimensional -- Diagnostic imaging
Dentistry -- Periodicals
Dentistry -- Periodicals
Dentisterie -- Périodiques
Electronic journals
617.6005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03005712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03005712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jdent.2020.103445 ↗
- Languages:
- English
- ISSNs:
- 0300-5712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4968.670000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14001.xml