Calibration of MTT assay in proton beams using radiochromic films. (September 2020)
- Record Type:
- Journal Article
- Title:
- Calibration of MTT assay in proton beams using radiochromic films. (September 2020)
- Main Title:
- Calibration of MTT assay in proton beams using radiochromic films
- Authors:
- Moftah, B.
Aldelaijan, S.
Shehadeh, M.
Alzorkany, F.
Alrumayan, F.
Alsbeih, G.
Alshabanah, M.
Seuntjens, J.
Tomic, N.
Devic, S. - Abstract:
- Highlights: Low energy proton beams. Radiochromic film dosimetry. Dose calibration for radiobiological experiments. Abstract: Purpose: This study provides methodology of calibrating as well as controlling the output for an MTT (3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide) colorimetric assay irradiated in a low energy proton beam using EBT3-model GAFCHROMIC TM film, without correcting for quenching effect. Methods: A calibrated Markus ionization chamber was used to measure the depth dose and beam output for 26.5 MeV protons produced by a CS30 cyclotron. A time-controlled aluminum cylinder was added in front of the horizontal beam-exit serving as a radiation shutter. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water at a reference depth of 3 mm. EBT3 film was calibrated for doses up to 8 Gy at the same depth. To verify the dose distribution for each 96-well MTT assay plate, EBT3 film was placed at the reference depth during irradiation and cell doses were scaled by measured percent depth dose (PDD) data. Results: The radiochromic film dosimetry system in this study provides dose measurements with an uncertainty better than 3.3% for doses higher than 1 Gy. From a single exposure and utilizing the Gaussian shape of the beam, multiple dose points can be obtained within different wells of the same plate ranging from 6.9 Gy (sigma ∼4%) in the central well, and 2 Gy (sigma ∼8%) for wells positioned closer toHighlights: Low energy proton beams. Radiochromic film dosimetry. Dose calibration for radiobiological experiments. Abstract: Purpose: This study provides methodology of calibrating as well as controlling the output for an MTT (3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide) colorimetric assay irradiated in a low energy proton beam using EBT3-model GAFCHROMIC TM film, without correcting for quenching effect. Methods: A calibrated Markus ionization chamber was used to measure the depth dose and beam output for 26.5 MeV protons produced by a CS30 cyclotron. A time-controlled aluminum cylinder was added in front of the horizontal beam-exit serving as a radiation shutter. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water at a reference depth of 3 mm. EBT3 film was calibrated for doses up to 8 Gy at the same depth. To verify the dose distribution for each 96-well MTT assay plate, EBT3 film was placed at the reference depth during irradiation and cell doses were scaled by measured percent depth dose (PDD) data. Results: The radiochromic film dosimetry system in this study provides dose measurements with an uncertainty better than 3.3% for doses higher than 1 Gy. From a single exposure and utilizing the Gaussian shape of the beam, multiple dose points can be obtained within different wells of the same plate ranging from 6.9 Gy (sigma ∼4%) in the central well, and 2 Gy (sigma ∼8%) for wells positioned closer to the periphery. Conclusions: We described a methodology for radiochromic film-based dose monitoring system, using low-energy protons, which can be used for the MTT assay in any proton beam, except within Bragg peak region. … (more)
- Is Part Of:
- Physica medica. Volume 77(2020)
- Journal:
- Physica medica
- Issue:
- Volume 77(2020)
- Issue Display:
- Volume 77, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 77
- Issue:
- 2020
- Issue Sort Value:
- 2020-0077-2020-0000
- Page Start:
- 146
- Page End:
- 153
- Publication Date:
- 2020-09
- Subjects:
- MTT assay -- Low energy proton beam -- Radiochromic film dosimetry
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.08.003 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 13998.xml