Duplex Ultrasound Investigation for the Detection of Obstructed Iliocaval Venous Stents. (September 2020)
- Record Type:
- Journal Article
- Title:
- Duplex Ultrasound Investigation for the Detection of Obstructed Iliocaval Venous Stents. (September 2020)
- Main Title:
- Duplex Ultrasound Investigation for the Detection of Obstructed Iliocaval Venous Stents
- Authors:
- Sebastian, Tim
Barco, Stefano
Engelberger, Rolf P.
Spirk, David
Schindewolf, Marc
Baumann, Frederic
Baumgartner, Iris
Kucher, Nils - Abstract:
- Abstract : Objective: Duplex ultrasound (DUS) is used for routine surveillance of stents in iliocaval veins, but direct visualisation is often challenging. Duplex ultrasound criteria for detecting venous stent obstruction (VSO) have not been defined to date. Methods: A nested case control study of 120 patients (42 ± 17 years, 53% women, mean 2.7 ± 1.8 stents) was performed, and the performance of various duplex parameters for detecting VSO (defined as > 50% lumen diameter reduction or occlusion) was tested, confirmed by biplane venography or intravascular ultrasound (IVUS). Forty patients with VSO (25 with stent occlusion, 15 with >50% in stent stenosis) were matched to 80 control patients by age, gender and index diagnosis who fulfilled the following criteria: (1) ongoing symptom control (Villalta score < 5), (2) good image quality of entire stent segment, (3) spontaneous colour Doppler signal > 50% of lumen in entire stent segment, (4) at least two DUS where the baseline DUS was obtained within 24 h after successful venous intervention. Results: The best test was the combination of peak flow velocity and flow pattern analysis at the stent inlet. A peak flow velocity >10 cm/s and a flow pattern spontaneously modulated by respiration ruled out VSO with a specificity of 93.7% (95% CI 86.0%–97.3%). A peak flow velocity ≤10 cm/s or any Doppler flow pattern other than spontaneously modulated by respiration was 92.1% (95% CI 79.2%–97.3%) sensitive to detect VSO. Conclusion: TheAbstract : Objective: Duplex ultrasound (DUS) is used for routine surveillance of stents in iliocaval veins, but direct visualisation is often challenging. Duplex ultrasound criteria for detecting venous stent obstruction (VSO) have not been defined to date. Methods: A nested case control study of 120 patients (42 ± 17 years, 53% women, mean 2.7 ± 1.8 stents) was performed, and the performance of various duplex parameters for detecting VSO (defined as > 50% lumen diameter reduction or occlusion) was tested, confirmed by biplane venography or intravascular ultrasound (IVUS). Forty patients with VSO (25 with stent occlusion, 15 with >50% in stent stenosis) were matched to 80 control patients by age, gender and index diagnosis who fulfilled the following criteria: (1) ongoing symptom control (Villalta score < 5), (2) good image quality of entire stent segment, (3) spontaneous colour Doppler signal > 50% of lumen in entire stent segment, (4) at least two DUS where the baseline DUS was obtained within 24 h after successful venous intervention. Results: The best test was the combination of peak flow velocity and flow pattern analysis at the stent inlet. A peak flow velocity >10 cm/s and a flow pattern spontaneously modulated by respiration ruled out VSO with a specificity of 93.7% (95% CI 86.0%–97.3%). A peak flow velocity ≤10 cm/s or any Doppler flow pattern other than spontaneously modulated by respiration was 92.1% (95% CI 79.2%–97.3%) sensitive to detect VSO. Conclusion: The combination of peak flow velocity and analysis of Doppler flow pattern at the stent inlet is accurate to diagnose or rule out stent occlusion. Indirect criteria should always be combined with direct visualisation of iliocaval stents since those may be less sensitive for detecting stent stenosis. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 60:Number 3(2020)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 60:Number 3(2020)
- Issue Display:
- Volume 60, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 60
- Issue:
- 3
- Issue Sort Value:
- 2020-0060-0003-0000
- Page Start:
- 443
- Page End:
- 450
- Publication Date:
- 2020-09
- Subjects:
- Duplex criteria -- Duplex ultrasound -- Post-thrombotic syndrome -- Stent surveillance -- Venous stent stenosis -- Venous stent thrombosis
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2020.05.011 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14000.xml