Quantitative analysis of endobronchial ultrasound elastography in computed tomography‐negative mediastinal and hilar lymph nodes. Issue 9 (21st July 2020)
- Record Type:
- Journal Article
- Title:
- Quantitative analysis of endobronchial ultrasound elastography in computed tomography‐negative mediastinal and hilar lymph nodes. Issue 9 (21st July 2020)
- Main Title:
- Quantitative analysis of endobronchial ultrasound elastography in computed tomography‐negative mediastinal and hilar lymph nodes
- Authors:
- Uchimura, Keigo
Yamasaki, Kei
Sasada, Shinji
Hara, Sachika
Ikushima, Issei
Chiba, Yosuke
Tachiwada, Takashi
Kawanami, Toshinori
Yatera, Kazuhiro - Abstract:
- Abstract : Background: Endobronchial ultrasound (EBUS) elastography assists in the differentiation of benign and malignant lymph nodes (LNs) during transbronchial needle aspiration (TBNA). However, previous studies have not compared B‐mode sonographic images (BSIs) and EBUS elastography images (EEIs) with final pathological diagnoses in radiologically normal‐sized (computed tomography [CT]‐negative) LNs. Methods: Consecutive patients with CT‐negative LNs, who received EBUS‐TBNA, were retrospectively reviewed. Images of BSIs and EEIs of each LN were stored and independently evaluated. EEIs were assessed by calculating the stiffness area ratio (SAR, blue/overall areas). The receiver operating characteristic curve was used to calculate the cutoff value for the SAR. Diagnostic test parameters were evaluated for each EBUS finding. Results: A total of 132 patients (149 LNs) were enrolled, and the median SAR of malignant LNs was significantly higher than that of benign LNs (0.58 vs. 0.32, P < 0.001). At the SAR cutoff of 0.41, the sensitivity, specificity, positive predictive value, negative predictive value (NPV), and diagnostic accuracy rate (DAR) of elastography were 88.2%, 80.2%, 78.9%, 89.0%, and 83.9%, respectively. The logistic regression analysis showed that elastography was the strongest predictor of malignancy (odds ratio, 18.5; 95% confidence interval [CI]: 6.48–52.6; P < 0.001). The highest NPV (96.6%) was achieved with a combination of BSIs and EEIs. Conclusions:Abstract : Background: Endobronchial ultrasound (EBUS) elastography assists in the differentiation of benign and malignant lymph nodes (LNs) during transbronchial needle aspiration (TBNA). However, previous studies have not compared B‐mode sonographic images (BSIs) and EBUS elastography images (EEIs) with final pathological diagnoses in radiologically normal‐sized (computed tomography [CT]‐negative) LNs. Methods: Consecutive patients with CT‐negative LNs, who received EBUS‐TBNA, were retrospectively reviewed. Images of BSIs and EEIs of each LN were stored and independently evaluated. EEIs were assessed by calculating the stiffness area ratio (SAR, blue/overall areas). The receiver operating characteristic curve was used to calculate the cutoff value for the SAR. Diagnostic test parameters were evaluated for each EBUS finding. Results: A total of 132 patients (149 LNs) were enrolled, and the median SAR of malignant LNs was significantly higher than that of benign LNs (0.58 vs. 0.32, P < 0.001). At the SAR cutoff of 0.41, the sensitivity, specificity, positive predictive value, negative predictive value (NPV), and diagnostic accuracy rate (DAR) of elastography were 88.2%, 80.2%, 78.9%, 89.0%, and 83.9%, respectively. The logistic regression analysis showed that elastography was the strongest predictor of malignancy (odds ratio, 18.5; 95% confidence interval [CI]: 6.48–52.6; P < 0.001). The highest NPV (96.6%) was achieved with a combination of BSIs and EEIs. Conclusions: EBUS elastography predicted malignant LNs with a high DAR and NPV in CT‐negative LNs. The NPV was highest when EEIs were combined with BSIs. Therefore, the combined evaluation of CT‐negative LNs using EEIs and BSIs may help bronchoscopists perform EBUS‐TBNA more efficiently. Key points: Significant findings of the study: Endobronchial ultrasound elastography accurately predicted malignancy with a high diagnostic accuracy rate and negative predictive value in radiologically normal‐sized lymph nodes. The additional use of B‐mode sonographic features resulted in a higher negative predictive value. What this study adds: Endobronchial ultrasound elastography can guide the accurate collection of specimens with transbronchial needle aspiration, even in radiologically normal‐sized lymph nodes. It can also readily distinguish benign and malignant lymph nodes, thus avoiding unnecessary punctures. Abstract : Endobronchial ultrasound elastography accurately predicted malignancy with a high diagnostic accuracy rate and negative predictive value in radiologically normal‐sized lymph nodes. The additional use of B‐mode sonographic features resulted in a higher negative predictive value. … (more)
- Is Part Of:
- Thoracic cancer. Volume 11:Issue 9(2020)
- Journal:
- Thoracic cancer
- Issue:
- Volume 11:Issue 9(2020)
- Issue Display:
- Volume 11, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 11
- Issue:
- 9
- Issue Sort Value:
- 2020-0011-0009-0000
- Page Start:
- 2590
- Page End:
- 2599
- Publication Date:
- 2020-07-21
- Subjects:
- Bronchoscopy -- elastography -- endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) -- lung cancer
Chest -- Cancer -- Periodicals
Chest -- Cancer -- Treatment -- Periodicals
Chest -- Surgery -- Periodicals
616.99494005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/%28ISSN%291759-7714;jsessionid=9202029487E02D838DF722140677202D.d04t01 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1759-7714 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.wiley.com/bw/journal.asp?ref=1759-7706&site=1 ↗ - DOI:
- 10.1111/1759-7714.13579 ↗
- Languages:
- English
- ISSNs:
- 1759-7706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.242500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14006.xml