Clinical outcomes of trabecular microbypass stent (iStent) implantation in medically controlled open-angle glaucoma in the Korean population. Issue 33 (14th August 2020)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes of trabecular microbypass stent (iStent) implantation in medically controlled open-angle glaucoma in the Korean population. Issue 33 (14th August 2020)
- Main Title:
- Clinical outcomes of trabecular microbypass stent (iStent) implantation in medically controlled open-angle glaucoma in the Korean population
- Authors:
- Kim, Hee Jun
Lim, Su-Ho - Other Names:
- Lee. Jacky section editor.
- Abstract:
- Abstract : Abstract: To evaluate the safety and efficacy [intraocular pressure (IOP)-lowering effect and medication use] of a single trabecular microbypass stent (iStent; Glaukos Corp, San Clemente, CA) for medically controlled open-angle glaucoma. This retrospective case series included 42 eyes of 34 patients with medically controlled open-angle glaucoma with IOP less than 21 mm Hg. Clinical outcomes analyzed were IOP, medication use, corrected distance visual acuity (CDVA), and surgical complications. Surgical success was defined according to 4 criteria: IOP < 21 mm Hg without medication; IOP < 18 mm Hg without medication; IOP < 15 mm Hg without medications; and IOP < 18 mm Hg with or without medication. Patients were followed for a minimum of 6 months postoperatively. Mean IOP was reduced from 15.8 ± 2.8 mm Hg to 14.5 ± 2.8 mm Hg ( P < .001), while mean number of medications decreased from 2.2 ± 1.2 to 0.8 ± 1.1 at final visit ( P < .001). Surgical success rates were 78.6%, 61.9%, 57.1%, and 97.6% at 6 months and 78.6%, 59.5%, 52.4%, and 95.2% at final visits according to criteria A, B, C, and D. Meanwhile, 59.5% of patients were medication-free at their final visit. The relative risk of surgical failure by Criteria B and C was 4.337 (95% confidence interval: 1.799–10.454) and 3.717 (95% confidence interval: 1.516–9.116) times greater in the higher-medication group (3 or more preoperative medications), respectively. CDVA was significantly improved from 0.41 ± 0.10 toAbstract : Abstract: To evaluate the safety and efficacy [intraocular pressure (IOP)-lowering effect and medication use] of a single trabecular microbypass stent (iStent; Glaukos Corp, San Clemente, CA) for medically controlled open-angle glaucoma. This retrospective case series included 42 eyes of 34 patients with medically controlled open-angle glaucoma with IOP less than 21 mm Hg. Clinical outcomes analyzed were IOP, medication use, corrected distance visual acuity (CDVA), and surgical complications. Surgical success was defined according to 4 criteria: IOP < 21 mm Hg without medication; IOP < 18 mm Hg without medication; IOP < 15 mm Hg without medications; and IOP < 18 mm Hg with or without medication. Patients were followed for a minimum of 6 months postoperatively. Mean IOP was reduced from 15.8 ± 2.8 mm Hg to 14.5 ± 2.8 mm Hg ( P < .001), while mean number of medications decreased from 2.2 ± 1.2 to 0.8 ± 1.1 at final visit ( P < .001). Surgical success rates were 78.6%, 61.9%, 57.1%, and 97.6% at 6 months and 78.6%, 59.5%, 52.4%, and 95.2% at final visits according to criteria A, B, C, and D. Meanwhile, 59.5% of patients were medication-free at their final visit. The relative risk of surgical failure by Criteria B and C was 4.337 (95% confidence interval: 1.799–10.454) and 3.717 (95% confidence interval: 1.516–9.116) times greater in the higher-medication group (3 or more preoperative medications), respectively. CDVA was significantly improved from 0.41 ± 0.10 to 0.09 ± 0.07 LogMAR in the combined phacoemulsification and iStent implantation group ( P < .001). There was no case whose vision was threatened (vision loss of 2 or more lines) or who showed severe complications after surgery. Single trabecular microbypass stent implantation was effective in reducing IOP and medication usage in patients with open-angle glaucoma with a low preoperative IOP. Our results imply that it is more difficult to achieve low target IOP control in eyes with higher numbers of preoperative medications. … (more)
- Is Part Of:
- Medicine. Volume 99:Issue 33(2020)
- Journal:
- Medicine
- Issue:
- Volume 99:Issue 33(2020)
- Issue Display:
- Volume 99, Issue 33 (2020)
- Year:
- 2020
- Volume:
- 99
- Issue:
- 33
- Issue Sort Value:
- 2020-0099-0033-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08-14
- Subjects:
- glaucoma -- MIGS -- POAG -- surgery -- trabecular microbypass stent
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000021729 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 13977.xml